{"product_id":"10012-1-2-honeywell-module-central-processing-unit-flash-memory","title":"10012\/1\/2 | Honeywell | Module Central Processing Unit Flash Memory","description":"\u003ch1\u003eHoneywell 10012\/1\/2 Module Central Processing Unit Flash Memory\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 10012\/1\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e10012\/1\/2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModule Central Processing Unit Flash Memory) operates as a processing and memory module within Honeywell safety control architectures. The module provides central processing functionality, analog signal acquisition, data handling, and execution support for control applications requiring monitored input processing and system-level diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10012\/1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModule Central Processing Unit Flash Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE; TÜV and UL approvals pending\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Class\u003c\/td\u003e\n\u003ctd\u003eAK1-6 (AK6 in redundant mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Software Version\u003c\/td\u003e\n\u003ctd\u003e= 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpace Requirement\u003c\/td\u003e\n\u003ctd\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC 35 mA; 24 VDC 35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0 V to 4.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Inaccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 LSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Inaccuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute Maximum Input Signal\u003c\/td\u003e\n\u003ctd\u003e+\/-36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Crosstalk\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Voltage Readback\u003c\/td\u003e\n\u003ctd\u003e0 V to 4.1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe 10012\/1\/2 module incorporates sixteen analog input channels with integrated analog-to-digital conversion capability. The input architecture supports voltage measurements from 0 V to 4.1 V while maintaining input resistance greater than 1 MOhm to minimize loading effects on connected field circuits.\u003c\/p\u003e\n\u003cp\u003eA 12-bit A\/D converter is utilized for signal digitization, with specified converter accuracy of +\/-1 LSB and overall module accuracy below 0.25%. Channel separation performance exceeds 60 dB cross-talk suppression, reducing signal interaction between adjacent input channels during acquisition and processing operations.\u003c\/p\u003e\n\u003cp\u003eExternal voltage readback functionality permits verification of input signal conditions through the module measurement circuitry, supporting diagnostic and maintenance activities.\u003c\/p\u003e\n\u003ch3\u003eRedundancy and Safety System Integration\u003c\/h3\u003e\n\u003cp\u003eThe module is designed for operation within Honeywell safety-related control environments and supports AK1-6 safety classifications. When deployed in redundant configurations, operation is specified for AK6 safety requirements.\u003c\/p\u003e\n\u003cp\u003ePower is supplied through both 5 VDC and 24 VDC system rails. The compact module form factor occupies 4 TE and 3 HE of rack space, enabling integration within high-density control system assemblies.\u003c\/p\u003e\n\u003cp\u003eSignal acquisition, processing operations, and diagnostic functions are synchronized through the CPU architecture to support control system execution requirements and monitored data handling functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input channels are available on the module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides 16 input channels for voltage signal acquisition.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum allowable input voltage?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe specified absolute maximum input signal is +\/-36 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide protection against channel interaction?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. Channel cross-talk suppression is specified at greater than 60 dB.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify software revision compatibility before installation into the target control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm proper rack space allocation of 4 TE and 3 HE before mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure power supply sources meet the specified 5 VDC and 24 VDC requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute low-level analog input wiring separately from high-current power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded instrumentation cables where required by plant engineering standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify input signal levels remain within the specified operating range before energizing the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform channel verification and diagnostic testing after installation and before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67670518071395,"sku":"10012\/1\/2","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/HONEYWELL10018-E-1.jpg?v=1776222903","url":"https:\/\/precisemodule.com\/products\/10012-1-2-honeywell-module-central-processing-unit-flash-memory","provider":"Precise Module Ltd.","version":"1.0","type":"link"}