{"product_id":"620-0081-honeywell-data-hiway-interface-module","title":"620-0081 | Honeywell | Data Hiway Interface Module","description":"\u003ch2\u003eHoneywell 620-0081 Data Hiway Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 620-0081 Data Hiway Interface Module\u003c\/strong\u003e is a communication interface module designed to connect IPC 620 programmable controllers to Honeywell Data Hiway networks used in TDC 2000 and TDC 3000 distributed control systems. It provides protocol conversion and network access between PLC-based control platforms and higher-level DCS infrastructure while supporting redundant communication paths for improved system availability.\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e620-0081\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eData Hiway Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eHoneywell Data Hiway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003eIPC 620-10, IPC 620-15, IPC 620-20, IPC 620-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eTDC 2000, TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+10% \/ -15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 W Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.44 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eDual BNC Coaxial Connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Redundancy\u003c\/td\u003e\n\u003ctd\u003eDual A\/B Network Paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e250 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Network Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 6,100 m (20,000 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSingle-Slot Plug-In Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e26.47 cm (10.43 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e2.92 cm (1.15 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e17.15 cm (6.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.80 kg (1.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eData Hiway Communication Function\u003c\/h3\u003e\n\u003cp\u003eThe 620-0081 serves as the communication bridge between IPC 620 controllers and Honeywell Data Hiway networks. Through this interface, controller data, status information, alarms, and process variables can be exchanged with supervisory systems operating within TDC architectures.\u003c\/p\u003e\n\u003cp\u003eThe module enables PLC-based control applications to participate in larger distributed control environments without requiring changes to the native controller operation.\u003c\/p\u003e\n\u003ch3\u003eNetwork Architecture Support\u003c\/h3\u003e\n\u003cp\u003eThe interface supports the proprietary Honeywell Data Hiway communication protocol used throughout TDC 2000 and TDC 3000 systems. This allows process information generated by IPC 620 controllers to be shared with operator stations, historical databases, and other networked control resources.\u003c\/p\u003e\n\u003cp\u003eBy providing protocol-level integration, the module extends the visibility of PLC-controlled processes into the plant-wide control network.\u003c\/p\u003e\n\u003ch3\u003eRedundant Communication Paths\u003c\/h3\u003e\n\u003cp\u003eTwo BNC coaxial connections are provided to support redundant A and B communication channels. This arrangement allows communication to continue in the event of a cable or network path fault, depending on the overall network architecture.\u003c\/p\u003e\n\u003cp\u003eRedundant network connectivity is particularly valuable in critical process applications where sustained controller-to-DCS communications are required.\u003c\/p\u003e\n\u003ch3\u003eCommunication Performance\u003c\/h3\u003e\n\u003cp\u003eThe module supports data transmission at 250 kbps over standard Honeywell coaxial network infrastructure. With suitable line drivers and network amplification equipment, communication distances can extend to 6,100 m (20,000 ft).\u003c\/p\u003e\n\u003cp\u003eThese capabilities allow deployment across large industrial facilities where controllers may be located significant distances from central control rooms.\u003c\/p\u003e\n\u003ch3\u003eInstallation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 620-0081 is supplied as a single-slot plug-in card for IPC 620 system chassis installations. Operating power is supplied from a 24 VDC source, with a maximum power consumption of 10.5 W.\u003c\/p\u003e\n\u003cp\u003eIts compact form factor allows integration into existing controller racks without requiring dedicated external communication hardware.\u003c\/p\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cp\u003eThe module is rated for operation between 0 deg C and 60 deg C and can be stored between -40 deg C and +85 deg C. Relative humidity ratings of 5% to 95% non-condensing support installation in typical industrial control environments when mounted within suitable enclosures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the Honeywell 620-0081?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides communication between IPC 620 PLC systems and Honeywell Data Hiway networks used in TDC 2000 and TDC 3000 control architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which controller platforms are supported?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Available specifications identify compatibility with IPC 620-10, IPC 620-15, IPC 620-20, and IPC 620-30 controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support redundant communications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module includes dual BNC coaxial interfaces for A and B communication paths, supporting redundant network connections where implemented.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67774358093923,"sku":"620-0081","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/620-0081_3.png?v=1792669620","url":"https:\/\/precisemodule.com\/products\/620-0081-honeywell-data-hiway-interface-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}