{"product_id":"abb-1mrk002246-bd-relion-670-communication-interface-module","title":"ABB 1MRK002246-BD Relion 670 Communication Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1MRK002246-BD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated Communication Interface Module for the ABB Relion 670 series, including RED670, REG670, and RES670 IEDs. This module provides high-speed, low-latency data transfer between protection devices and substation networks, ensuring reliable operation for time-critical applications. It supports both optical fiber and galvanic Ethernet connections, making it suitable for harsh substation environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports fast GOOSE messaging with sub-3ms latency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMicrosecond-accurate time synchronization via IEEE 1588 (PTP) or IRIG-B\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandles sampled values for real-time protection and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy and Reliability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eParallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains continuous data flow during network failures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: -25°C to +55°C (short-term up to +70°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh immunity to EMI and electrostatic discharge per IEC 60255\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for substation-level electrical noise and surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFully integrated with ABB Relion 670 chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable design for maintenance without system downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multi-protocol communication including IEC 61850-8-1, IEC 61850-9-2, DNP 3.0, and IEC 60870-5-103\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003e16-Channel Analog Input Capability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn addition to communication functions, the module interfaces with analog inputs for monitoring purposes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e16 universal channels for voltage, current, or resistance measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput ranges: 0–10V, 0–20mA, 4–20mA, 0–50mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 16-bit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ±0.05% of reading\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSampling rate: up to 100 samples per second per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully isolated inputs for safe measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply: 24VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental ratings: Operating -20°C to +60°C, Storage -40°C to +80°C, Humidity 0–95% RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSubstation automation and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time protection communication between IEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring of critical analog process signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into IEC 61850-compliant network systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module handle multiple communication protocols simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it manages multiple stacks without impacting the main CPU performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is hot-swapping supported?\u003c\/strong\u003e\u003cbr\u003eA: Yes, modules can be replaced without shutting down the IED.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which network media are supported?\u003c\/strong\u003e\u003cbr\u003eA: Optical fiber via SFP modules and galvanic Ethernet ports.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44130954477667,"sku":"1MRK002246-BD","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABB1MRK002246-BD-2.jpg?v=1776753608","url":"https:\/\/precisemodule.com\/products\/abb-1mrk002246-bd-relion-670-communication-interface-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}