{"product_id":"abb-1vcr017053g0001-multi-voltage-power-supply-board-vsc-series","title":"ABB 1VCR017053G0001 Multi-Voltage Power Supply Board | VSC Series","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1VCR017053G0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance power supply and control board designed for ABB’s VSC series medium-voltage vacuum contactors. It acts as the central interface between external control signals and the bistable magnetic actuator inside the contactor, ensuring precise and reliable switching operations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Voltage Input:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 24–60V AC\/DC and 110–250V AC\/DC inputs, configurable via jumper settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnergy Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors and regulates storage capacitor voltage to guarantee proper actuation even during brief voltage dips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Standby Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignificant current is drawn only during charging and switching; minimal power is consumed while holding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Protection Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes under-voltage trip, anti-pumping protection, and status feedback via LEDs or dry contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports over 1,000,000 mechanical operations under harsh environmental conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003e1VCR017053G0001\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eVSC\/P, VSC\/F, VSC\/PN Vacuum Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24–60V or 110–250V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e50\/60 Hz (AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 12 kV (system context)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 400 A (typical for VSC system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e160 mm × 90 mm × 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eApprox. 0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt; 50 ms for typical switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eService Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026gt;1,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOptional Coating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDNV-certified coating for offshore or marine environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial HVAC systems for large compressors and chillers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy machinery and mining motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary transformer and pump control in power generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eModel Comparison\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG0001 vs G0006:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eG0001 is optimized for wider auxiliary voltage ranges and capacitor charging profiles, while G0006 targets standard voltage applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board operate with both AC and DC inputs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports a wide range of AC and DC auxiliary voltages configurable via jumpers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it protect the contactor from repeated closure attempts?\u003c\/strong\u003e\u003cbr\u003eA: Anti-pumping logic prevents repeated closure if a continuous signal is present during fault conditions.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44142733623395,"sku":"1VCR017053G0001","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABB1VCR017053G0001-3.jpg?v=1777252329","url":"https:\/\/precisemodule.com\/products\/abb-1vcr017053g0001-multi-voltage-power-supply-board-vsc-series","provider":"Precise Module Ltd.","version":"1.0","type":"link"}