{"product_id":"abb-ai880a-3bse028586r1-high-integrity-analog-input-module","title":"ABB AI880A | 3BSE028586R1 | High Integrity Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB AI880A (3BSE028586R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8-channel\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHigh Integrity Analog Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS800 I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Designed for critical industrial applications, the module provides precise monitoring of 0–20 mA and 4–20 mA signals with advanced self-diagnostics and internal redundancy. Ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-instrumented systems\u003c\/strong\u003e, it meets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards when paired with compatible controllers, ensuring reliable data acquisition in demanding environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSIL3 Safety Integrity\u003c\/strong\u003e\u003cbr\u003eThe AI880A incorporates a \"1oo2\" microprocessor architecture that continuously cross-checks input measurements, ensuring no single hardware fault leads to unsafe process states.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHART Pass-Through Capability\u003c\/strong\u003e\u003cbr\u003eSupports HART 5, 6, and 7 protocols, enabling remote configuration of smart transmitters, retrieval of diagnostic data, and access to secondary process variables without affecting primary signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Self-Diagnostics\u003c\/strong\u003e\u003cbr\u003eContinuous internal monitoring of A\/D converters, voltage references, and memory detects inconsistencies, automatically placing the module into a safe state and alerting the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Field Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach input channel is protected against short circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtects the controller backplane from transient disturbances and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Accuracy and Resolution\u003c\/strong\u003e\u003cbr\u003e12-bit resolution ensures precise signal measurement, with minimal temperature drift (max. 50 ppm\/°C), linear response, and reliable performance under fluctuating environmental conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAI880A High Integrity Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3BSE028586R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA Unipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Level\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL3 (with HI controller)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHART Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHART 5, 6, 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250 Ω (with TY801 shunt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 ms hardware (rise time 0–90%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverrange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+12% for 0–20 mA, +15% for 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Non-Destructive Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 m (656 yards)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC via MTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront LEDs (F, R, W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–55 °C (32–131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40–70 °C (-40–158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830 (high integrity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, UL, ATEX, ABS, DNV, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (IEC 60664-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSafety-Critical Process Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for Emergency Shutdown Systems (ESD), Fire \u0026amp; Gas (F\u0026amp;G), and other SIL3 safety applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-integrity input for chemical, oil \u0026amp; gas, and manufacturing process control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote or Redundant Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports both single and redundant configurations for reliable operation in critical environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eMounting and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMust be installed with a compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModule Termination Unit (MTU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as TU810, TU812, TU814, or TU830 for redundant high-integrity operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure firm seating and proper locking on the ModuleBus connector to maintain reliable communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm cable lengths and field connections comply with S800 I\/O specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the input resolution of the AI880A?\u003c\/strong\u003e\u003cbr\u003eA: The module provides 12-bit resolution, enabling precise analog measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it handle HART transmitters?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports HART 5, 6, and 7 without interrupting the primary 4–20 mA signal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it certified for safety-critical applications?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the AI880A is SIL3 certified when used with a high integrity controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I configure it for single and redundant operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports both configurations to meet system safety requirements.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44133716197475,"sku":"AI880A","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABBAI880A-3.jpg?v=1776842884","url":"https:\/\/precisemodule.com\/products\/abb-ai880a-3bse028586r1-high-integrity-analog-input-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}