{"product_id":"abb-cmt1000-control-and-monitoring-terminal-1khl150030r0001","title":"ABB CMT1000 Control and Monitoring Terminal | 1KHL150030R0001","description":"\u003cp\u003e\u003cspan\u003eShopify Product Title:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eABB CMT1000 | Control and Monitoring Terminal | 1KHL150030R0001 | ETL600 Power Line Carrier\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eABB CMT1000 (Part Number: 1KHL150030R0001)\u003c\/span\u003e is a high-performance \u003cspan\u003eControl and Monitoring Terminal\u003c\/span\u003e designed for use in ABB’s \u003cspan\u003eETL600 Power Line Carrier (PLC)\u003c\/span\u003e system and other telecommunication frameworks in power utilities. This modular, rack-mounted terminal functions as a \u003cspan\u003eHuman-Machine Interface (HMI)\u003c\/span\u003e and local management unit for configuring, monitoring, and supervising communication links in electrical substations. The \u003cspan\u003eCMT1000\u003c\/span\u003e is critical for the transmission of teleprotection, voice, and data signals over high-voltage power lines, providing a centralized point for diagnostics, alarm management, and system parameterization.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eKey Technical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModel Number:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCMT1000\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProduct ID:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e1KHL150030R0001\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem Compatibility:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB ETL600\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eABB FOX515\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUtility Communication Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDisplay Type:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated \u003cspan\u003eLED\/LCD\u003c\/span\u003e Status Indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInterfaces:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet (RJ45)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS-232\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLocal Maintenance Port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInput Voltage:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e36 Vdc to 72 Vdc\u003c\/span\u003e (Standard substation battery)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProtocols Supported:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSNMP\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHTTP\u003c\/span\u003e (Web-based management)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIEC 60870-5-101\/104\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Temperature Range:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e-10°C to +55°C\u003c\/span\u003e (14°F to 131°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e19-inch Rack-mount\u003c\/span\u003e (Subrack integrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eWeb-Based Management:\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e includes an embedded web server, allowing users to configure the entire \u003cspan\u003eETL600 link\u003c\/span\u003e via a standard web browser without requiring proprietary software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEvent Logging:\u003c\/span\u003e\u003cbr\u003eIt features detailed logging of \u003cspan\u003esystem alarms\u003c\/span\u003e, \u003cspan\u003epower levels\u003c\/span\u003e, and \u003cspan\u003elink stability\u003c\/span\u003e, which is crucial for \u003cspan\u003epost-fault analysis\u003c\/span\u003e in power grids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSNMP Integration:\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e supports \u003cspan\u003eSimple Network Management Protocol (SNMP)\u003c\/span\u003e, allowing integration into higher-level \u003cspan\u003eNetwork Management Systems (NMS)\u003c\/span\u003e, including ABB’s \u003cspan\u003eFOXMAN\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundant Access:\u003c\/span\u003e\u003cbr\u003eBoth \u003cspan\u003elocal (front panel)\u003c\/span\u003e and \u003cspan\u003eremote (networked)\u003c\/span\u003e access are available, ensuring system management is possible even if the primary control network fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eSystem Role\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eIn a \u003cspan\u003eutility communication network\u003c\/span\u003e, the \u003cspan\u003eCMT1000\u003c\/span\u003e plays the following critical roles:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommissioning:\u003c\/span\u003e\u003cbr\u003eConfigures frequency pairs and bandwidth for the power line carrier system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMonitoring:\u003c\/span\u003e\u003cbr\u003eMonitors the \u003cspan\u003eSignal-to-Noise Ratio (SNR)\u003c\/span\u003e and \u003cspan\u003eline attenuation\u003c\/span\u003e of the high-voltage carrier link to ensure optimal communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlarming:\u003c\/span\u003e\u003cbr\u003eTriggers alarms (Critical, Major, or Minor) if communication link degradation is detected, notifying the substation’s \u003cspan\u003eSCADA system\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cspan\u003eMaintenance \u0026amp; Troubleshooting\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStatus LEDs:\u003c\/span\u003e\u003cbr\u003eThe front panel includes \u003cspan\u003eSystem Healthy\u003c\/span\u003e (green) and \u003cspan\u003eGeneral Alarm\u003c\/span\u003e (red) LEDs. If the red LED is lit, the \u003cspan\u003eCMT1000\u003c\/span\u003e web interface provides the specific error code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFirmware Updates:\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e manages \u003cspan\u003efirmware distribution\u003c\/span\u003e for other sub-modules in the \u003cspan\u003eETL600 rack\u003c\/span\u003e. During system upgrades, ensure the \u003cspan\u003eCMT1000\u003c\/span\u003e is updated first to ensure proper operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBattery Backup:\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e is powered by the \u003cspan\u003esubstation DC bus\u003c\/span\u003e but includes an internal backup battery (if equipped) to preserve settings during a power failure. Regular checks should be performed during \u003cspan\u003efive-year maintenance cycles\u003c\/span\u003e to ensure continuity of service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTechnical Note:\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e acts as the \u003cspan\u003eSystem Controller\u003c\/span\u003e for the rack. If removed, the communication links (Voice\/Data) may still function, but \u003cspan\u003emanagement, monitoring, and teleprotection alarms\u003c\/span\u003e will be lost.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eWhat is the primary function of the CMT1000?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e serves as the \u003cspan\u003eControl and Monitoring Terminal\u003c\/span\u003e for the \u003cspan\u003eETL600 Power Line Carrier system\u003c\/span\u003e, allowing for configuration, management, and monitoring of communication links within substations and utility communication systems.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eIs the CMT1000 compatible with other ABB systems?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eYes, the \u003cspan\u003eCMT1000\u003c\/span\u003e is compatible with \u003cspan\u003eABB’s ETL600, FOX515\u003c\/span\u003e, and other \u003cspan\u003eutility communication systems\u003c\/span\u003e, making it an essential piece of equipment in ABB’s power line carrier infrastructure.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eCan the CMT1000 be managed remotely?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eYes, the \u003cspan\u003eCMT1000\u003c\/span\u003e supports both \u003cspan\u003elocal\u003c\/span\u003e and \u003cspan\u003eremote management\u003c\/span\u003e through \u003cspan\u003eEthernet\u003c\/span\u003e, \u003cspan\u003eRS-232\u003c\/span\u003e, and \u003cspan\u003eweb-based interfaces\u003c\/span\u003e, providing redundancy in case of network failures.\u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eWhat kind of alarms does the CMT1000 handle?\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eCMT1000\u003c\/span\u003e can trigger \u003cspan\u003eCritical\u003c\/span\u003e, \u003cspan\u003eMajor\u003c\/span\u003e, and \u003cspan\u003eMinor\u003c\/span\u003e alarms based on communication link degradation, which can be reported to a substation's \u003cspan\u003eSCADA system\u003c\/span\u003e.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44096036372579,"sku":"CMT1000","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/CMT1000_5aca0651-a003-4936-b13e-d6c2853a1d53.jpg?v=1775027874","url":"https:\/\/precisemodule.com\/products\/abb-cmt1000-control-and-monitoring-terminal-1khl150030r0001","provider":"Precise Module Ltd.","version":"1.0","type":"link"}