{"product_id":"abb-cs513-3bse000435r1-real-time-accelerator-board-advant-ocs","title":"ABB CS513 3BSE000435R1 Real-Time Accelerator Board Advant OCS","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS513 (3BSE000435R1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Real-Time Accelerator (RTA) board engineered for the ABB Advant OCS (Open Control System). It serves as a dedicated communication co-processor in Advant Station 500 series workstations and AC 400 series controllers, managing MasterBus 300 (MB 300) network traffic independently to preserve deterministic timing on the host system.\u003c\/p\u003e\n\u003cp\u003eThis board handles the protocol stack directly on the hardware, offloading the CPU from intensive network processing tasks and ensuring reliable real-time data flow. Its design emphasizes speed, precision, and robustness, making it integral to mission-critical industrial control applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDedicated Protocol Processing\u003c\/strong\u003e\u003cbr\u003eThe board includes an onboard microprocessor and memory, enabling it to manage MB 300 telegram framing, error detection, and retransmission independently. This offloading guarantees consistent timing for process data, critical in real-time control environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Throughput Data Transfer\u003c\/strong\u003e\u003cbr\u003eOptimized for large-volume process data, the CS513 enables fast updates of operator displays, alarms, and historical data streams without compromising system responsiveness.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Performance\u003c\/strong\u003e\u003cbr\u003eEngineered as a Real-Time Accelerator, it prioritizes time-sensitive data, minimizing latency and jitter, ensuring reliable delivery of control commands and emergency signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Reliability\u003c\/strong\u003e\u003cbr\u003eConstructed to meet rigorous Advant Master standards, the board supports continuous 24\/7 operation. It includes self-diagnostics with power-on self-tests (POST) and runtime monitoring, with status LEDs providing instant visual feedback.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless System Integration\u003c\/strong\u003e\u003cbr\u003eOnce configured via AdvaBuild or ABB Aspect Object, the board automatically maps process objects across the network, reducing manual configuration and simplifying system deployment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eReal-Time Accelerator (RTA) Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCS513\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3BSE000435R1\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Support\u003c\/td\u003e\n\u003ctd\u003eMasterBus 300 (MB 300)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHost Interface\u003c\/td\u003e\n\u003ctd\u003eGSB or PCI Carrier Bus (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eOnboard microcontroller for protocol handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eOnboard RAM for telegram buffering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10–15 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e234 mm × 160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eAdvant Station 500, AC 410, AC 450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eSelf-diagnostics, Real-Time Data Handling, Deterministic Protocol Timing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Jitter\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms in standard configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed HMI updates in Advant Station environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical process monitoring requiring real-time determinism\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork protocol offloading in AC 400 series controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial environments with continuous 24\/7 operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What happens if network timeouts occur?\u003c\/strong\u003e\u003cbr\u003eA: Check MB 300 physical connections and 75-ohm terminators. Issues often originate from bus termination rather than the CS513 board itself.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the board be used in systems other than Advant Station 500?\u003c\/strong\u003e\u003cbr\u003eA: It is specifically designed for Advant Station 500 and AC 400 series controllers. Use in other systems may not be supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it require software configuration?\u003c\/strong\u003e\u003cbr\u003eA: Minimal configuration is needed via AdvaBuild or ABB Aspect Object to map process objects across the network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the expected lifespan in industrial use?\u003c\/strong\u003e\u003cbr\u003eA: The CS513 is built for long-term 24\/7 operation under typical Advant OCS conditions.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44131333734499,"sku":"CS513","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABBCS513-3.jpg?v=1776761590","url":"https:\/\/precisemodule.com\/products\/abb-cs513-3bse000435r1-real-time-accelerator-board-advant-ocs","provider":"Precise Module Ltd.","version":"1.0","type":"link"}