{"product_id":"abb-fau810-flame-analysis-unit-abb-flame-scanner-module","title":"ABB FAU810 Flame Analysis Unit | ABB Flame Scanner Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB FAU810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFlame Analysis Unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered to monitor and analyze flame conditions in industrial combustion systems. It interprets optical signals from ABB flame detectors, such as the SF810 series, ensuring safe and efficient operation in boilers, furnaces, and multi-burner installations.\u003c\/p\u003e\n\u003cp\u003eDesigned for integration into ABB AC800M platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFAU810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides real-time flame status to control systems, distinguishing between valid flame signals and background noise or spurious radiation. Its intelligent processing minimizes false trips and ensures continuous plant operation.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Flame Signal Processing\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFAU810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eevaluates flicker frequency, flame intensity, and stability to accurately detect the presence of combustion flames. Its algorithms differentiate between primary flame regions, background radiation, and multiple burner sources.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Response \u0026amp; Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUltra-fast response times (\u0026lt;1 second) suitable for critical safety applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable flame-on\/off thresholds for precise control and emergency shutdown logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSIL 3 capable when deployed with ABB flame scanner systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIntegration \u0026amp; Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multiple sensor inputs and redundant flame channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides analog 4–20 mA output for flame intensity and dry-contact relays for flame status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRS-485 Modbus RTU communication enables seamless connection to DCS or PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with ABB configuration software for live flame monitoring and tuning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDurability \u0026amp; Reliability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail mounting with rugged housing suitable for high-temperature, electrically noisy environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelf-diagnostics constantly monitor hardware and sensor integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperational temperature range: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eFAU810 (Flame Analysis Unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eABB AC800M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDetection Principle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eOptical flame detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSensing Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 10 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt;1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePulse or Analog from Flame Scanners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4–20 mA (Intensity), Relay (Status), Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eFlicker Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAdjustable for fuel\/burner types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e35 mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e27 cm × 9 cm × 19 cm (10.63 × 3.54 × 7.48 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.5 kg (1.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eMulti-burner furnaces, boilers, sulfur recovery units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimized Nuisance Trips:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced signal discrimination reduces unnecessary shutdowns\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Commissioning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital interface simplifies configuration and parameter tuning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for high-temperature, vibration-prone, and electrically noisy industrial environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous self-diagnostics and dual-channel monitoring ensure flame presence accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which sensors are compatible with FAU810?\u003c\/strong\u003e\u003cbr\u003eA: Compatible with ABB SF810 series flame scanners and similar optical detectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can FAU810 monitor multiple burners?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Dual-channel configuration supports multiple sensors for safety-critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does it communicate with control systems?\u003c\/strong\u003e\u003cbr\u003eA: Provides analog 4–20 mA, relay contacts, and RS-485 Modbus RTU output for integration with DCS or PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What fuels can it detect?\u003c\/strong\u003e\u003cbr\u003eA: Supports coal, oil, natural gas, and other industrial fuels with adjustable flame flicker frequency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is FAU810 suitable for extreme temperatures?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Rated for -40°C to +85°C, suitable for challenging industrial environments.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":43659457921123,"sku":"FAU810","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABBFAU810.jpg?v=1776156108","url":"https:\/\/precisemodule.com\/products\/abb-fau810-flame-analysis-unit-abb-flame-scanner-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}