{"product_id":"abb-imcpm03-multi-function-processor-infi-90-net-90-module","title":"ABB IMCPM03 Multi-Function Processor | INFI 90 \/ Net 90 Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IMCPM03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMulti-Function Processor (MFP) Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eINFI 90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetwork 90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. It serves as the primary intelligence for a Control Unit, performing high-level control, managing I\/O data, and facilitating communication across the control network. The module is ideal for continuous, batch, and sequential control applications in complex industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel \/ Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIMCPM03\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eMulti-Function Processor (MFP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCompatible Systems\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eINFI 90, Network 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eMotorola 68000 Series High-Performance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMemory (RAM)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e512 KB to 1 MB, battery-backed for retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 64 Slave Modules via I\/O Expander Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInstruction Execution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHigh-speed processing of functional blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eInterfaces with NIS\/NPM for Cnet connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e+5 VDC from MMU backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eApproximately 10 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e16-segment front-panel LED for status and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5.1 cm x 17.8 cm x 33.0 cm (2.0\" x 7.0\" x 13.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.4 kg (13.6 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProgramming Tools\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eABB Composer or WinCAD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eConfigurable in redundant pair with bumpless transfer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNon-Volatile Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eBattery-backed RAM preserves configuration and process data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Control Library:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports PID loops, timers, logic gates, mathematical functions, and custom functional blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen paired, a secondary IMCPM03 automatically takes over without interrupting the process in case of a primary failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Programming:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOnline configuration changes are possible using standard ABB engineering tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelf-tests detect bus errors, battery voltage issues, or hardware faults, displaying error codes on the front LED.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintains critical configuration and process variables during power outages for rapid recovery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plants, water\/wastewater treatment, and chemical processing facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess control and monitoring in cement, pulp and paper, petrochemical, pharmaceutical, and food industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control in metallurgical, petroleum, textile, and other industrial systems requiring high reliability and centralized intelligence.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003eEnsure the onboard battery is functional to maintain configuration and process data. Verify Address Select Dip-switch settings before installation to avoid conflicts on the I\/O bus. The module is rack-mounted in standard MMU slots and integrates with NIS\/NPM for network communication.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated ABB Models\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eXVC768102, 3BHB007211R102, 5SGY3545L0010, 3BHB006485R0001, 3BHB030310R0001, 5SHY4045L0006, 5SHY3545L0010, 3BHB013088R0001, 3BHE009681R0101, GVC750BE101\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What control strategies can IMCPM03 execute?\u003c\/strong\u003e\u003cbr\u003eA: Continuous, batch, and sequential control using PID, timers, and custom function blocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it operate in redundant mode?\u003c\/strong\u003e\u003cbr\u003eA: Yes, a secondary IMCPM03 can take over automatically without process interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is configuration preserved during power loss?\u003c\/strong\u003e\u003cbr\u003eA: Battery-backed RAM maintains configuration and process data for smooth recovery.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44120767529059,"sku":"IMCPM03","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABBIMCPM03-3.jpg?v=1776304298","url":"https:\/\/precisemodule.com\/products\/abb-imcpm03-multi-function-processor-infi-90-net-90-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}