{"product_id":"abb-spfec12-pulse-input-slave-module-symphony-plus-harmony","title":"ABB SPFEC12 Pulse Input Slave Module Symphony Plus\/Harmony","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB SPFEC12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePulse Input Slave Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for Symphony Plus and Harmony (Network 90\/INFI 90) control systems. It accurately converts pulse signals from field devices into engineering units, enabling precise process monitoring and control. The module supports both high-speed frequency measurement and totalized pulse accumulation, making it ideal for critical flow, speed, and energy applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel \/ Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSPFEC12\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePulse Input Slave Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4 isolated input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePulse \/ Frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.1 Hz – 50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Voltage Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5V, 12V, 24V, Magnetic Pickup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.01% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e16-bit frequency, 32-bit pulse count\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1500 Vrms (channel-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eApprox. 3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHeight: 358.14 mm, Width: 269.24 mm, Depth: 71.12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSelectable hardware and software filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSelf-monitoring for signal validity and hardware integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDual-module configuration available for critical applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Mode Operation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannels can operate independently for instantaneous frequency measurement or pulse totalization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtects the controller from voltage spikes and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMagnetic Pickup Ready:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccepts low-voltage magnetic signals without external preamplifiers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects signal errors and reports status to the HMI for faster troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports redundant configurations for continuous operation in turbine or motor speed applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine flow metering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpeed measurement via tachometers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower and energy totalization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed pulse monitoring in industrial processes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Note\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eProper jumper configuration on the module is critical for accurate operation. Ensure voltage levels are set correctly (e.g., 24V vs. millivolt magnetic pickups) to avoid signal loss or erroneous readings.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can SPFEC12 handle high-speed signals?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports up to 50 kHz input frequency with 0.01% accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it compatible with redundant systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes, two modules can operate in parallel to provide continuous monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it interface directly with magnetic pickups?\u003c\/strong\u003e\u003cbr\u003eA: Yes, low-voltage magnetic pickup sensors are supported without external amplification.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44120562630755,"sku":"SPFEC12","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABBSPFEC12-3.jpg?v=1776301974","url":"https:\/\/precisemodule.com\/products\/abb-spfec12-pulse-input-slave-module-symphony-plus-harmony","provider":"Precise Module Ltd.","version":"1.0","type":"link"}