{"product_id":"abb-spnpm22-network-processing-module-bailey-infi-90-control","title":"ABB SPNPM22 Network Processing Module | Bailey INFI 90 Control","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB SPNPM22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetwork Processing Module (NPM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSymphony Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHarmony (INFI 90)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. It functions as the primary communication hub for plant-wide data, efficiently linking controllers, I\/O modules, and other networked devices while enabling advanced control and monitoring capabilities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel \/ Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSPNPM22\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eNetwork Processing Module (Master)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eControl System Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSymphony Plus, Harmony (INFI 90), Bailey INFI-NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eHigh-speed 32-bit RISC CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eExpanded Flash and RAM for large database management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNetwork Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCnet: 2 Mbaud \/ 10 Mbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eThroughput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUp to 5,000 exception reports per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eNode Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSupports up to 250 local I\/O modules\/slaves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eApprox. 5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e16-segment LED display for status and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eDimensions (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e16 × 16 × 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e85389091\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Communication Hub:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDirects data flow between local controllers and the plant-wide Cnet, enabling seamless network integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Message Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimizes traffic by prioritizing exception reporting, sending only updated data to reduce network congestion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDatabase Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintains a local copy of the node database for rapid point data access without overloading the main controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Ready:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports hot-standby operation with a secondary SPNPM22 for full fault-tolerant performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in LED display provides immediate status feedback and error reporting for efficient troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime Synchronization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures millisecond-accurate timestamps for all control events and sequence-of-events recording.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cblockquote\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPNPM22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis configured via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS+ Engineering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eComposer\u003c\/strong\u003e. For redundant setups, firmware versions must match across modules. Typically installed in the first slots of a network node to manage interface between the control station and the plant network.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePlant-wide Ethernet network integration for Bailey INFI-NET systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed control optimization across multiple nodes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time data collection and exception reporting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with legacy and modern DCS networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial facilities requiring high-speed communication and network reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the SPNPM22 used for?\u003c\/strong\u003e\u003cbr\u003eA: It serves as the master network processing module, managing communication and data flow in Symphony Plus and Harmony control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can SPNPM22 work with redundant pairs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports hot-standby redundancy for uninterrupted network operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What network speeds does it support?\u003c\/strong\u003e\u003cbr\u003eA: Cnet speeds of 2 Mbaud and 10 Mbaud, with high throughput for large-scale systems.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44120762843235,"sku":"SPNPM22","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/ABBSPNPM22-3.jpg?v=1776303646","url":"https:\/\/precisemodule.com\/products\/abb-spnpm22-network-processing-module-bailey-infi-90-control","provider":"Precise Module Ltd.","version":"1.0","type":"link"}