{"product_id":"bently-nevada-105m6001-01-i-o-module-3701-46-adapt-hydro-monitor","title":"Bently Nevada 105M6001-01 I\/O Module | 3701\/46 ADAPT Hydro Monitor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 105M6001-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInput\/Output (I\/O) Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3701\/46 ADAPT Hydro Turbine Monitoring System\u003c\/strong\u003e. It provides a robust interface for low-speed hydro turbine sensors, including proximity probes, air gap transducers, and velocity\/seismic sensors. The module conditions and transmits these critical signals to the ADAPT processor, ensuring accurate condition monitoring and reliable protection for hydroelectric units.\u003c\/p\u003e\n\u003cp\u003eOptimized for \"at-the-machine\" installation, the 105M6001-01 ensures high signal integrity in environments with strong magnetic fields and electrical noise, while supporting autonomous turbine protection even in the event of network failures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eHydro-Specific Sensor Integration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with low-frequency proximity probes for shaft and bearing monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports air gap sensors for rotor-stator clearance measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccepts velocity and seismic transducers to monitor structural vibration and generator frame movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eHigh-Density Channel Architecture\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple dynamic channels for upper and lower guide bearing coverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDedicated Keyphasor inputs for synchronous speed\/phase measurements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConsolidates several monitoring points into a single compact module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eSignal Conditioning \u0026amp; Buffered Outputs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides clean, EMI-protected power to connected sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuffered output connectors enable live diagnostics with portable analyzers without interrupting protection logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures accurate signal transmission in harsh hydroelectric environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eDistributed Protection \u0026amp; Data Capture\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports autonomous trip capability within the local hydro unit protection loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCaptures transient events during start-up, coast-down, and load changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWorks with ADAPT processor to integrate real-time protection and condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eRugged Industrial Design\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature range: -30°C to +65°C (-22°F to +149°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: -40°C to +85°C (-40°F to +185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity tolerance: 0–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration and shock rated to IEC 60068 standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHazardous area approvals: Class I, Div 2 and ATEX\/IECEx Zone 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eProduct ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e105M6001-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eModule Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eInput\/Output (I\/O) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eBently Nevada 3701\/46 ADAPT Hydro Turbine Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eProximity, Accelerometer, Velomitor, Air Gap Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMounting Options\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e3701 Terminal Base \/ DIN Rail \/ 3500 Rack Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eCommunication\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eInternal Bus to 3701 Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5 g, 57–500 Hz (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eShock Resistance\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e15 g, 11 ms (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAltitude\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt;2000 m (6,562 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePollution Degree\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eInstallation Category\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHydroelectric turbine monitoring for low-speed shafts and guide bearings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotor-stator air gap measurement for large generators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStructural vibration analysis of turbine and generator housings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOn-site, skid-mounted deployment in hydro plants with strong EMI and magnetic fields\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module handle multiple sensor types simultaneously?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, the 105M6001-01 supports proximity probes, accelerometers, velomitors, and air gap sensors concurrently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does it require a separate power supply?\u003c\/strong\u003e\u003cbr\u003eA2: No, it draws power directly from the 3500 or 3701 rack system, simplifying installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does it differ from general ADAPT modules?\u003c\/strong\u003e\u003cbr\u003eA3: It is optimized for hydro turbine monitoring, including low-speed vibration and air gap measurements, which are not supported on gas turbine-focused modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: What is required for proper sensor grounding?\u003c\/strong\u003e\u003cbr\u003eA4: Use the correct Terminal Base for shield grounding to prevent false alarms caused by generator magnetic fields.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44118679388259,"sku":"105M6001-01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/105M6001-01.jpg?v=1774860388","url":"https:\/\/precisemodule.com\/products\/bently-nevada-105m6001-01-i-o-module-3701-46-adapt-hydro-monitor","provider":"Precise Module Ltd.","version":"1.0","type":"link"}