{"product_id":"bently-nevada-125720-02-4-channel-relay-output-module","title":"Bently Nevada 125720-02 4-Channel Relay Output Module","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 125720-02 4-Channel Relay Output Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe Bently Nevada 125720-02, also cataloged as the 3500\/32 4-Channel Relay Output Module, operates as a dedicated hardware component for alarm and trip logic execution within the 3500 Rack monitoring system.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e125720-02\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.45 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.3 x 11 x 24 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 deg C to +85 deg C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDerived from Rack Backplane\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 A per channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Switched Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e450 VA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 VAC \/ 30 VDC (Resistive)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe 125720-02 module functions as the final control element within the TSI rack, facilitating binary state transitions based on rotor dynamics and vibration alarm setpoints. Each of the four integrated relays supports independent Alarm Drive Logic, allowing for complex voting schemes (e.g., 2oo3 or majority voting) when integrated with Alert and Danger status signals. The hardware architecture suppresses signal cross-talk between logic channels, ensuring deterministic execution of trip commands for fluid-film bearing machines. The module interfaces directly with the backplane bus, enabling high-speed relay actuation triggered by Not-OK or sensor threshold violations detected by upstream monitor modules.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be hot-swapped while the 3500 rack is powered and operating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Yes, the 125720-02 module supports hot-swapping. However, ensure that the relay output circuits are safely isolated or in a bypass state to prevent unintended machine trips during the module replacement process.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is it possible to program individual relay voting logic for each of the four channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Yes. Each output is independently programmable using the 3500 Rack Configuration Software, utilizing logic combinations of Alert, Danger, and Not-OK statuses from any monitor channel within the rack.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eEnsure the module is fully seated in the rack backplane to establish secure communication with the Transient Data Interface (TDI).\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eVerify that the wiring connected to the relay terminals does not exceed the 2 A limit to prevent contact pitting or relay failure.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eUse shielded cabling for all field output wiring to minimize electromagnetic interference (EMI) pick-up, particularly in environments with high-frequency switching transients.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003ePerform a functional loop test after installation to confirm that the relay drive logic triggers the intended field actuators (e.g., solenoids or trip valves).\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eObserve proper torque specifications when terminating wires to the terminal blocks to prevent loose connections under thermal expansion cycles.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44367609593955,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/126648-01-1_651debc1-fc1f-4d3b-b000-6d69c5488f59.jpg?v=1784257269","url":"https:\/\/precisemodule.com\/products\/bently-nevada-125720-02-4-channel-relay-output-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}