{"product_id":"bently-nevada-127610-01-3500-25-keyphasor-i-o-module-3500-15-power","title":"Bently Nevada 127610-01 3500\/25 Keyphasor I\/O Module | 3500\/15 Power","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/15 (127610-01 + 125840-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower solution provides reliable energy delivery for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500 Series Machinery Protection System\u003c\/strong\u003e, supporting both AC and DC input sources. Its modular design accommodates single or redundant configurations, ensuring continuous operation in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e127610-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeyphasor® I\/O Module integrates with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/25 Enhanced Keyphasor System\u003c\/strong\u003e, serving as the rear-mounted interface for Proximity Probes and Magnetic Pickups. It delivers precise timing signals essential for rotational speed tracking, phase analysis, and vibration diagnostics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply Module (3500\/15)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAccepts a wide range of AC inputs:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e175–264 Vac RMS (220 Vac nominal), 247–373 Vac pk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e85–132 Vac RMS (110 Vac nominal), 120–188 Vac pk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency support:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e47–63 Hz\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput: Regulated power to rack modules, typically\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 W\u003c\/strong\u003e; extended variants up to 500 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant operation: Dual modules for backup, installed in the left-most rack slots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-30°C to +65°C\u003c\/strong\u003e, storage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +85°C\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity tolerance: Up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e95% RH, non-condensing\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eKeyphasor I\/O Module (127610-01)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHalf-height module installed at rear rack position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent Keyphasor transducers\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 XL Proximity Probes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMagnetic Pickups\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides highly accurate timing pulses for phase determination and speed tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical isolation protects the 3500 system backplane from transducer-side surges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAPI 670 compliant for machinery protection standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuffered outputs allow connection to diagnostic equipment without affecting the protection loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500\/15 \u0026amp; 3500\/25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Numbers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127610-01, 125840-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKeyphasor I\/O \u0026amp; Universal Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Keyphasor inputs per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity Probes, Magnetic Pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 100 W (variants 200–500 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHalf-height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Slot\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLeft-most for power, rear for I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial machinery protection systems requiring redundant power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision phase and speed measurement for rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration monitoring, orbit plotting, and diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with 3500\/25 Enhanced Keyphasor monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the power module be replaced while the system is live?\u003c\/strong\u003e\u003cbr\u003eA: Yes, provided a second module is installed; the system maintains operation during hot-swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many Keyphasor signals can this I\/O module handle?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e127610-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports two independent Keyphasor inputs per module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require an external termination block?\u003c\/strong\u003e\u003cbr\u003eA: No, it uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal terminations\u003c\/strong\u003e; for an External Termination Block, use a different part number (e.g., 125800-01).\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44133777965155,"sku":"127610-01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/BENTLYNEVADA127610-01_8a1142b4-0040-4adf-946c-021e5aec0ca0.jpg?v=1776846245","url":"https:\/\/precisemodule.com\/products\/bently-nevada-127610-01-3500-25-keyphasor-i-o-module-3500-15-power","provider":"Precise Module Ltd.","version":"1.0","type":"link"}