{"product_id":"bently-nevada-138607-01-dual-transient-data-interface-module-3500-series","title":"Bently Nevada 138607-01 Dual Transient Data Interface Module 3500 Series","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance Dual Transient Data Interface (TDI) module designed for the 3500 Series machinery protection system. Installed in the rear of the 3500 rack, this module provides a direct interface for vibration sensors, enabling both static and dynamic data acquisition. Its internal termination design allows for straightforward wiring, eliminating the need for external terminal blocks, and supporting seamless integration with diagnostic software such as GE System 1.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCore Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eData Acquisition and Processing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed Ethernet and USB connectivity for transferring large volumes of waveform and vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapable of capturing transient events including machine startups, coast-downs, and alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous sampling across channels ensures precise phase correlation for orbit analysis and shaft centerline calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical and Environmental Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInternal termination reduces installation complexity and conserves rack space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-swappable module allows replacement without shutting down the 3500 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged design tolerates harsh industrial environments, with high EMI and vibration resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with the 3500\/22M TDI system to maintain reliable sensor-to-network communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully adheres to API 670 standards for machinery protection and condition monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports RUN and PROGRAM modes for controlled configuration and operation, with a removable key to prevent unauthorized changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eModule Type\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDual Transient Data Interface (TDI) I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eTermination\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eInternal Termination (Direct Wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eProximitor, Accelerometer, Velomitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eEthernet (10\/100 Base-T), USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eUnpowered Shelf Life\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e12 Years at 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eData Rate\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e115.2 kbaud max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMounting\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eRear slot of 3500 Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eProtocol\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eBN Host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eKeylock Modes\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eRUN \/ PROGRAM, removable key, remote reconfiguration support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eFront Panel LEDs\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eOK, TX\/RX, TM, CONFIG OK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eIdeal for predictive maintenance, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e138607-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis critical for capturing diagnostic data that explains vibration trends and transient behaviors in rotating machinery. It complements standard 3500 modules that focus on trips and protection, enabling engineers to analyze and prevent equipment failures.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 138607-01 module?\u003c\/strong\u003e\u003cbr\u003eIt serves as a high-speed interface for transient data collection between the 3500 rack and diagnostic software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be replaced while the system is powered?\u003c\/strong\u003e\u003cbr\u003eYes, the hot-swappable design allows installation or replacement without downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do RUN and PROGRAM modes work?\u003c\/strong\u003e\u003cbr\u003eRUN mode allows normal operation and prevents configuration changes. PROGRAM mode allows remote or local configuration, with a removable key for security.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich sensors are compatible?\u003c\/strong\u003e\u003cbr\u003eProximitor probes, accelerometers, and velomiters are fully supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much waveform and static data is collected during an alarm?\u003c\/strong\u003e\u003cbr\u003eStatic data: 1 second 10 minutes before, 1 minute after alarm; Waveform: 2.5 minutes at 10-second intervals prior, 1 minute post-alarm.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44133821546595,"sku":"138607-01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/BENTLYNEVADA138607-01-3_c0670d5c-8593-4fae-b408-f4f094c2065c.jpg?v=1776849337","url":"https:\/\/precisemodule.com\/products\/bently-nevada-138607-01-dual-transient-data-interface-module-3500-series","provider":"Precise Module Ltd.","version":"1.0","type":"link"}