{"product_id":"bently-nevada-330100-90-05-proximitor-sensor","title":"Bently Nevada 330100-90-05 Proximitor Sensor","description":"\u003ch2\u003eBently Nevada 330100-90-05 Proximitor Sensor\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-frequency signal conditioning within rotating machinery monitoring networks, the \u003cstrong\u003eBently Nevada 330100-90-05\u003c\/strong\u003e (\u003cstrong\u003e330100-90-05\u003c\/strong\u003e Proximitor Sensor) provides direct physical\/electrical execution for gap-to-voltage conversion. This sensor acts as the primary hardware interface to translate eddy-current probe responses into precise static position and dynamic vibration data across the monitoring loop.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Standard Specifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e330100\u003c\/td\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e3300 Proximitor Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e9.0 meters (total length including probe and cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eMultiple approvals \/ Agency certification option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330100-90-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 x 22.2 x 3.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 VDC to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProportional voltage output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBently Nevada Mechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e330100-90-05\u003c\/strong\u003e Proximitor sensor is calibrated to maintain linearity within the 3300 system architecture, ensuring that rotor dynamics data is captured without signal degradation. The unit facilitates gap voltage validation at the nominal -10 VDC target, allowing for accurate phase reference and axial position tracking. By utilizing high-frequency modulation, the sensor minimizes the impact of cross-talk within multi-channel racks. It is imperative that the coaxial cabling maintained between the probe tip and the sensor does not deviate from the 9.0 meter system specification, as this length is critical to the internal impedance matching required for maintaining the specified probe sensitivity and signal-to-noise ratio.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 330100-90-05 be used with a 5 meter extension cable instead of the specified 9 meter configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: No. The system is calibrated for a specific total length. Altering the cable length will shift the linear range and introduce errors in the output voltage, necessitating system re-calibration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this sensor support hot-swap capabilities in a 3300 series rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: While the Proximitor itself is a modular component, ensure the power supply to the specific channel is verified before disconnection to prevent transient voltage spikes in the monitoring loop.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Install the sensor in a clean, dry, and non-hazardous area within the plant instrumentation enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Utilize the integral mounting base to attach the unit to a standard DIN rail. Ensure a robust electrical connection to the chassis ground for noise immunity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Maintenance\u003c\/strong\u003e: Inspect coaxial connectors for signs of corrosion or moisture. Ensure the connection is fully seated and tightened finger-tight plus 1\/8 turn.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Ensure the coaxial shield is maintained throughout the path and tied to a single-point ground at the monitoring instrument, avoiding ground loops that can compromise vibration data accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44366344519779,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/330100-90-05-1.jpg?v=1784185929","url":"https:\/\/precisemodule.com\/products\/bently-nevada-330100-90-05-proximitor-sensor","provider":"Precise Module Ltd.","version":"1.0","type":"link"}