{"product_id":"bently-nevada-330103-00-06-10-02-05-3300-xl-8-mm-proximity-probe","title":"Bently Nevada 330103-00-06-10-02-05 3300 XL 8 mm Proximity Probe","description":"\u003ch2\u003eBently Nevada 330103-00-06-10-02-05 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330103-00-06-10-02-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330103\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for static (position) and dynamic (vibration) measurements within machine turbine supervisory instrumentation (TSI) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-00-06-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.08 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e113.0 x 1.8 x 1.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor (driven by Proximitor Sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Calibration\u003c\/h3\u003e\n\u003cp\u003eThe 330103-00-06-10-02-05 utilizes eddy-current probe scaling to convert physical distance into a proportional electrical signal via the Proximitor loop. Field verification requires rigid adherence to gap voltage validation targets. The nominal gap voltage calibration point is set at -10 VDC, corresponding to the center of the 2.0 mm linear displacement range. System integration eliminates the requirement for bench calibration due to full interchangeability between the 3300 XL 8 mm probes, extension cables, and Proximitor sensors. Cross-talk suppression must be maintained by isolating the probe cabling from adjacent high-voltage power lines to protect the integrity of the rotor dynamics data stream.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is a bench calibration required when replacing only the 330103 probe?\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 XL 8 mm components provide complete interchangeability, eliminating the requirement to match or bench calibrate individual components or loops.\u003c\/p\u003e\n\u003cp\u003eQ: Is this 3300 XL probe backward compatible with legacy non-XL 3300 series systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Each component is backward compatible and interchangeable with non-XL 3300 series 5 mm and 8 mm transducer components, subject to total system length constraints.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Protection:\u003c\/strong\u003e Ensure the extension cable connection is tight and insulated using self-fusing silicone tape or a dedicated connector protector to prevent fluid contamination and electrical grounding faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget Gap Validation:\u003c\/strong\u003e Adjust the probe mechanically within the housing until the digital multimeter indicates a gap voltage of -10 VDC (+\/-0.5 VDC) at the Proximitor sensor test points, ensuring the probe tip is positioned in the center of its linear range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRouting Limitations:\u003c\/strong\u003e Maintain physical separation between transducer cables and high-power AC lines. Run probe wiring inside dedicated, grounded metal conduits to suppress electromagnetic interference (EMI) and signal crosstalk.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #e74c3c;\"\u003e\u003cspan style=\"font-size: 20px;\"\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44319324864611,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/330103-00-06-10-02-05-2.jpg?v=1783326367","url":"https:\/\/precisemodule.com\/products\/bently-nevada-330103-00-06-10-02-05-3300-xl-8-mm-proximity-probe","provider":"Precise Module Ltd.","version":"1.0","type":"link"}