{"product_id":"bently-nevada-330104-10-20-10-02-cn-3300-xl-proximity-probe","title":"Bently Nevada 330104-10-20-10-02-CN 3300 XL Proximity Probe","description":"\u003ch2\u003eBently Nevada 330104-10-20-10-02-CN 3300 XL Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330104-10-20-10-02-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330104\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for static position and dynamic vibration measurements within machinery monitoring systems. It functions as part of the 3300 XL 8 mm Proximity Transducer System, producing an output voltage directly proportional to the physical gap between the probe tip and the observed conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330104-10-20-10-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8 mm probe tip diameter, custom reverse-mount\/threaded body configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +218 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConsumes power via Proximitor Sensor loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils) nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Proximitor Sensor and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterchangeability\u003c\/td\u003e\n\u003ctd\u003eFully backward compatible with non-XL 3300 5 mm and 8 mm components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProximity Transducer Mechanical Monitoring Attributes\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm system requires strict gap voltage validation to maintain standard eddy-current probe scaling across the full linear range. Field technicians execute verification protocols targeting -10 VDC at the physical center point of the measurement gap to secure linear calibration. This precise mechanical positioning minimizes errors in rotor dynamics assessment and optimizes cross-talk suppression when multiple transducer probes are clustered in close proximity around the shaft area.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this probe require matching or bench calibration with specific system cables?\u003c\/p\u003e\n\u003cp\u003eA: No. All 3300 XL 8 mm hardware components feature complete cross-component interchangeability, allowing replacement of probes, cables, or sensors without re-calibration.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 3300 XL component be used with older, non-XL 3300 transducer systems?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware is backward compatible and interchangeable with standard non-XL 3300 series 5 mm and 8 mm transducer components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the installation housing matches the specific reverse-mount or threaded physical envelope of the probe body to prevent mechanical distortion. Thread the probe into place while tracking output voltage until reaching the standard -10 VDC gap setting on a calibrated voltmeter. Secure the outer locknuts according to specified industrial limits to prevent loosening from machinery vibration, and protect all coaxial junctions inside an environmental conduit to prevent fluid contamination.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44318686150755,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/330104-00-23-10-02-00-1.jpg?v=1783318278","url":"https:\/\/precisemodule.com\/products\/bently-nevada-330104-10-20-10-02-cn-3300-xl-proximity-probe","provider":"Precise Module Ltd.","version":"1.0","type":"link"}