{"product_id":"bently-nevada-330171-00-94-10-02-00-cable","title":"Bently Nevada 330171-00-94-10-02-00 Cable","description":"\u003ch1 data-path-to-node=\"0\"\u003e\u003cb data-path-to-node=\"0\" data-index-in-node=\"0\"\u003eBently Nevada 330171-00-94-10-02-00 Cable\u003c\/b\u003e\u003c\/h1\u003e\n\u003cp data-path-to-node=\"1\"\u003e\u003cb data-path-to-node=\"1\" data-index-in-node=\"0\"\u003eThe Bently Nevada 330171-00-94-10-02-00\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"63\"\u003e3300 XL\u003c\/b\u003e extension cable, operates as a dedicated hardware component for signal transmission between the proximity probe and the Proximitor sensor within fluid-film bearing monitoring systems.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003e\u003cb data-path-to-node=\"2\" data-index-in-node=\"0\"\u003eHardware Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003e\u003cb data-path-to-node=\"3,1,0,0\" data-index-in-node=\"0\"\u003eModel\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003e\u003cb data-path-to-node=\"3,1,1,0\" data-index-in-node=\"0\"\u003e330171-00-94-10-02-00\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003e\u003cb data-path-to-node=\"3,2,0,0\" data-index-in-node=\"0\"\u003eBrand\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003e\u003cb data-path-to-node=\"3,2,1,0\" data-index-in-node=\"0\"\u003eBently Nevada\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003e\u003cb data-path-to-node=\"3,3,0,0\" data-index-in-node=\"0\"\u003eOrigin\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003e\u003cb data-path-to-node=\"3,3,1,0\" data-index-in-node=\"0\"\u003eUSA\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003e\u003cb data-path-to-node=\"3,4,0,0\" data-index-in-node=\"0\"\u003eWeight\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e\u003cb data-path-to-node=\"3,4,1,0\" data-index-in-node=\"0\"\u003e0.5 kg\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003e\u003cb data-path-to-node=\"3,5,0,0\" data-index-in-node=\"0\"\u003eDimensions\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003e\u003cb data-path-to-node=\"3,5,1,0\" data-index-in-node=\"0\"\u003e9.4 meters (Cable Length)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003e\u003cb data-path-to-node=\"3,6,0,0\" data-index-in-node=\"0\"\u003eOperating Temp\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003e\u003cb data-path-to-node=\"3,6,1,0\" data-index-in-node=\"0\"\u003e-51 deg C to +177 deg C\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003e\u003cb data-path-to-node=\"3,7,0,0\" data-index-in-node=\"0\"\u003ePower Consumption\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003e\u003cb data-path-to-node=\"3,7,1,0\" data-index-in-node=\"0\"\u003eN\/A (Passive Component)\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003e\u003cb data-path-to-node=\"3,8,0,0\" data-index-in-node=\"0\"\u003ePerformance\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003e\u003cb data-path-to-node=\"3,8,1,0\" data-index-in-node=\"0\"\u003eCompatible with 3300 XL 5 mm\/8 mm Systems\u003c\/b\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003e\u003cb data-path-to-node=\"4\" data-index-in-node=\"0\"\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003e\u003cb data-path-to-node=\"5\" data-index-in-node=\"0\"\u003eThe 3300 XL extension cable is engineered to maintain system-wide interchangeability, ensuring the transducer system meets established rotor dynamics specifications without requiring bench calibration. The cable impedance is factory-matched to the 3300 XL Proximitor sensor, which is vital for maintaining the -10 VDC gap voltage target at the Proximitor output. Proper installation of this cable is required to prevent signal attenuation and cross-talk suppression issues that could otherwise induce noise in the dynamic vibration signal path. The integrity of the coaxial shield connection remains critical to maintaining a linear output voltage proportional to the probe tip gap.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"0\"\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"0\"\u003eQ: Is it necessary to recalibrate the Proximitor sensor when replacing this 9.4-meter extension cable?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cb data-path-to-node=\"7\" data-index-in-node=\"103\"\u003eA: No. The 3300 XL system is designed for complete interchangeability. Replacing the extension cable does not necessitate bench calibration or individual component matching, provided the cable is the correct length and part number.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"0\"\u003eQ: Can this extension cable be used with non-XL 3300 series proximity sensors?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003e\u003cb data-path-to-node=\"8\" data-index-in-node=\"79\"\u003eA: No. The 3300 XL series components are specifically impedance-matched. Using XL extension cables with older non-XL components will result in signal measurement errors and incorrect gap voltage outputs.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"10\"\u003e\u003cb data-path-to-node=\"10\" data-index-in-node=\"0\"\u003eField Installation Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003e\u003cb data-path-to-node=\"11,0,0\" data-index-in-node=\"0\"\u003eEnsure the cable connectors are cleaned with high-grade electrical contact cleaner before assembly to prevent oxidation at the connection point.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003e\u003cb data-path-to-node=\"11,1,0\" data-index-in-node=\"0\"\u003eDo not exceed the minimum bend radius of the coaxial cable during installation to avoid internal shield damage or characteristic impedance changes.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003e\u003cb data-path-to-node=\"11,2,0\" data-index-in-node=\"0\"\u003eWhen routing the cable, maintain adequate separation from high-voltage power lines and VFD output cables to minimize electromagnetic interference (EMI).\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003e\u003cb data-path-to-node=\"11,3,0\" data-index-in-node=\"0\"\u003eSecure the cable using authorized cable ties or conduit systems to prevent mechanical fatigue caused by machine casing vibration.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003e\u003cb data-path-to-node=\"11,4,0\" data-index-in-node=\"0\"\u003eVerify the gap voltage at the Proximitor output after installation to ensure the reading aligns with the expected baseline for the specific bearing clearance.\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44367584231523,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/330171-00-94-10-02-00-1_de1c3df3-784e-4cca-8aea-8f70c742e74e.jpg?v=1784256810","url":"https:\/\/precisemodule.com\/products\/bently-nevada-330171-00-94-10-02-00-cable","provider":"Precise Module Ltd.","version":"1.0","type":"link"}