{"product_id":"bently-nevada-3500-05-01-01-00-00-00-system-rack","title":"Bently Nevada 3500\/05-01-01-00-00-00 System Rack","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/05-01-01-00-00-00 System Rack\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe Bently Nevada 3500\/05-01-01-00-00-00, also cataloged as the 3500\/05 System Rack, operates as a dedicated hardware component for machinery monitoring and protection within the 3500 Machinery Protection System.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription \/ Standard Specifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/05\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eRack Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e19-inch Full-Size Rack (14 module slots)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Mount Option, Full-Size Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNone\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eReserved\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eNone\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/05-01-01-00-00-00\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.95 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e48.2 cm x 28.0 cm x 26.5 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 deg C to 70 deg C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eVariable by configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable Module Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003ePanel Mount\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical Monitoring and TSI Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe Bently Nevada 3500\/05 chassis serves as the central backplane for transient data acquisition and signal processing. Accurate eddy-current probe scaling relies on the stable -24 VDC bus provided by the rack power supplies. The backplane design ensures low-latency communication between monitor modules and the Transient Data Interface (TDI), facilitating high-fidelity rotor dynamics monitoring. During installation, verify that gap voltage validation (-10 VDC targets) is maintained across all input channels to ensure the integrity of proximity-to-vibration signal conversion. Internal bus structures are engineered for cross-talk suppression to maintain signal-to-noise ratios in high-density monitoring environments.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 3500\/05 rack support mixed-mode installation of monitor and relay modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Yes, the 14 available slots in the full-size rack accept any combination of 3500 monitor, relay, or Keyphasor modules, provided the Rack Interface Module (RIM\/TDI) and Power Supplies occupy the designated far-left positions.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary requirement for panel mounting this chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: The chassis requires a rectangular panel cut-out of specific dimensions to accommodate the flange. Secure the rack using the provided clamping hardware to ensure structural rigidity against mechanical vibration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003ePanel Cut-out Preparation: Ensure the panel aperture conforms to manufacturing tolerances to allow for a flush fit. Use the provided clamps to secure the rack, ensuring even pressure distribution around the flange.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eBackplane Access: For panel-mounted configurations, ensure adequate clearance is available behind the panel for cable management, I\/O module insertion, and maintenance access.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eGrounding and Shielding: Connect the rack chassis to a verified clean instrument earth. Use high-quality shielded twisted-pair cabling for all transducer inputs, ensuring the shield is terminated only at the I\/O module barrier to prevent ground loops.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eSystem Integrity: Always install blanking panels in unused slots. This maintains the structural integrity of the rack and ensures proper airflow for heat dissipation across the internal backplane circuitry.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44367816261731,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/3500-05-01-01-00-00-00-1.jpg?v=1784260483","url":"https:\/\/precisemodule.com\/products\/bently-nevada-3500-05-01-01-00-00-00-system-rack","provider":"Precise Module Ltd.","version":"1.0","type":"link"}