{"product_id":"bently-nevada-3500-22-125768-01-transient-data-interface-module","title":"Bently Nevada 3500\/22 125768-01 Transient Data Interface Module","description":"\u003ch2\u003eBently Nevada 3500\/22 125768-01 Transient Data Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for transient waveform data acquisition and rack communication in the Bently Nevada 3500 monitoring system, the \u003cstrong\u003eBently Nevada 125768-01\u003c\/strong\u003e (\u003cstrong\u003e3500\/22\u003c\/strong\u003e Transient Data Interface Module) provides direct data collection and Ethernet communication functions between 3500 M-series monitor modules and compatible condition monitoring software platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e125768-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 11.2 x 24.2 cm (estimated shipping size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC supply, 145 mA typical module current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTransient Data Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position\u003c\/td\u003e\n\u003ctd\u003eSlot 1 adjacent to power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8 x 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 % of span @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 - 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eEthernet data transfer to host software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Software\u003c\/td\u003e\n\u003ctd\u003eSystem 1 Condition Monitoring and Diagnostic Software, 3500 System Configuration Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTransient Data Acquisition and Ethernet Communication Interface\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22M Transient Data Interface combines the rack interface functions of the 3500\/20 Rack Interface Module with communication processor capabilities for collecting machinery monitoring data. The module interfaces with M-series monitors such as 3500\/40M and 3500\/42M to acquire steady-state values and transient dynamic waveform data.\u003c\/p\u003e\n\u003cp\u003eThe TDI provides standard static data capture capability. When used with an optional Channel Enabling Disk, the module can collect dynamic and high-resolution transient data for diagnostic analysis. The integrated communication processor transfers collected data through an Ethernet connection to compatible host software.\u003c\/p\u003e\n\u003cp\u003eThe 3500\/22 module operates outside the automatic machinery protection signal path. Although it provides rack-level communication and data handling functions, it does not affect normal monitor operation or protection logic execution. Each 3500 rack requires one TDI or RIM module installed in Slot 1 adjacent to the power supply modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 3500\/22 TDI part of the machinery protection monitoring path?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The TDI provides communication and data collection functions but is not part of the critical monitoring path used for automatic machinery protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where is the 125768-01 module installed in a 3500 rack?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module is installed in Slot 1, directly adjacent to the power supply modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of data can the TDI collect?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The TDI collects steady-state monitoring data as standard and can collect dynamic waveform and high-resolution transient data when configured with the required optional channel enabling function.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the 3500\/22 module only in Slot 1 of the 3500 rack next to the power supply modules.\u003c\/li\u003e\n\u003cli\u003eVerify the rack contains only one TDI or RIM interface module as required by the system configuration.\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet communication wiring according to the installed host software network requirements.\u003c\/li\u003e\n\u003cli\u003eSeparate communication cables from high-voltage power wiring to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eVerify 24 VDC supply wiring polarity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eConfirm monitor module compatibility before enabling transient waveform data collection functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan style=\"font-size: 14px;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #e74c3c;\"\u003e\u003cspan style=\"font-size: 20px;\"\u003e\u003cspan style=\"font-family: Arial,Helvetica,sans-serif;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44330318299235,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/125768-01-1_6f07d24a-590d-4c81-856e-c6f153b98ef1.jpg?v=1783475506","url":"https:\/\/precisemodule.com\/products\/bently-nevada-3500-22-125768-01-transient-data-interface-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}