{"product_id":"bently-nevada-3500-22m-138607-01-transient-data-interface-module","title":"Bently Nevada 3500\/22M 138607-01 Transient Data Interface Module","description":"\u003ch2\u003eBently Nevada 3500\/22M 138607-01 Transient Data Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for steady state and transient dynamic waveform data collection in 3500 Series Machinery Protection Systems, the \u003cstrong\u003eBently Nevada 3500\/22M 138607-01\u003c\/strong\u003e (\u003cstrong\u003e3500\/22M\u003c\/strong\u003e Transient Data Interface) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/22M 138607-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 25.3 cm x 24.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Interface\u003c\/td\u003e\n\u003ctd\u003eUSB-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply Current\u003c\/td\u003e\n\u003ctd\u003eless than 1 mAdc, Dry Contact to Common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integration\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22M 138607-01 acts as the communication link to continuously collect static and transient dynamic parameters from downstream M series monitors. During eddy-current probe scaling verification, the module facilitates the collection of raw waveform telemetry essential for evaluating rotor dynamics behaviors such as shaft centerline motion and orbits. Grounded cross-talk suppression and digital isolation maintain the clarity of phase reference signals and gap voltage validation targets during high-amplitude machine transients, allowing high-resolution data capture without influencing the independent hardware shutdown loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does a failure or removal of the 3500\/22M 138607-01 impact the machinery protection functions of the rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The module resides outside the critical monitoring protection path. Its extraction or loss of power does not interrupt or degrade the automatic machinery shutdown loops driven by adjacent monitoring cards.\u003c\/p\u003e\n\u003cp\u003eQ: What is required to activate high-resolution dynamic and transient data capture on this unit?\u003c\/p\u003e\n\u003cp\u003eA: Static data capture is fully standard within the factory hardware configuration. Enabling continuous high-resolution transient and dynamic waveform data collection requires the application of an optional external Channel Enabling Disk activation file.\u003c\/p\u003e\n\u003cp\u003eQ: What is the peak current rating for the front panel Trip Multiply input interface?\u003c\/p\u003e\n\u003cp\u003eA: The Trip Multiply circuit requires a dry contact interface connected to system common, pulling a maximum current of less than 1 mAdc during continuous activation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThe module must be installed solely in the designated slot directly adjacent to the 3500 power supplies. Ensure alignment slots are matched before applying physical pressure.\u003c\/li\u003e\n\u003cli\u003eTighten all rear chassis terminal fasteners and front faceplate panel screws to standard specification lines to maintain electrical chassis bonding.\u003c\/li\u003e\n\u003cli\u003eKeep external communication Ethernet runs separated from high-voltage motor or actuator conduits to mitigate parasitic electromagnetic interference. All field transducer shields must maintain single-point termination grounding protocols to prevent internal signal disruption.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44317094281315,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/138607-01-1.jpg?v=1783302622","url":"https:\/\/precisemodule.com\/products\/bently-nevada-3500-22m-138607-01-transient-data-interface-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}