{"product_id":"bently-nevada-3500-40-126615-01-proximitor-monitors","title":"Bently Nevada 3500\/40 126615-01 Proximitor Monitors","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/40 126615-01 Proximitor Monitors\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eThe Bently Nevada 3500\/40, also cataloged as the 126615-01 Proximitor-I\/O-Module, operates as a dedicated hardware component for signal routing and proximity transducer termination within the 3500 Machinery Protection System platform.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3500\/40 (126615-01)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eBently Nevada\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUSA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.4 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2.5 x 11.2 x 24.2 cm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-30 deg C to +65 deg C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e-40 deg C to +85 deg C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eUp to 95% RH (non-condensing)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8 W typical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eRotor Dynamics and Gap Voltage Validation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOperating within the framework of machinery protection architecture, this rear I\/O module interfaces directly with proximity transducers to route raw vibration and position signals to the associated front monitor module. The internal circuitry manages eddy-current probe scaling and maintains strict gap voltage validation targets across all four input channels. Signal integrity is preserved through robust shielding and backplane routing, suppressing electrical cross-talk and supporting precise evaluation of radial vibration, thrust position, and rotor dynamics.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 126615-01 Proximitor-I\/O-Module be replaced without powering down the entire 3500 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Yes, rear I\/O modules support hot-insertion and removal when executed in coordination with front monitor slot protocols, provided proper safety measures for live industrial maintenance are followed.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are transducer signals terminated and protected against noise interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA: Termination is handled directly via dedicated terminal blocks on the module, utilizing standard shielding practices to ground incoming signal cables and prevent electromagnetic interference.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Placement: Mount the module into the designated rear slot directly aligned with its corresponding 3500\/40M front monitor module within the rack frame.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Grounding: Terminate all proximity transducer cables securely to the module's connectors while ensuring shield drain wires are properly grounded to mitigate noise.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVerification: Check environmental operating limits and confirm secure mechanical latching prior to powering the instrument rack.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44386929705059,"sku":null,"price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/126615-01-1.jpg?v=1784689832","url":"https:\/\/precisemodule.com\/products\/bently-nevada-3500-40-126615-01-proximitor-monitors","provider":"Precise Module Ltd.","version":"1.0","type":"link"}