{"product_id":"emerson-ovation-5x00070g01-16-channel-digital-input-module","title":"Emerson Ovation 5X00070G01 | 16-Channel Digital Input Module","description":"\u003ch4 data-start=\"301\" data-end=\"316\"\u003eOverview\u003c\/h4\u003e\n\u003cp data-start=\"317\" data-end=\"777\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"321\" data-end=\"351\"\u003eEmerson Ovation 5X00070G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a highly reliable\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"373\" data-end=\"403\"\u003eDigital Input\/Output (DIO)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule designed for use in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"435\" data-end=\"479\"\u003eOvation Distributed Control System (DCS)\u003c\/strong\u003e. It is specifically engineered for high-performance process control in critical applications like\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"578\" data-end=\"594\"\u003epower plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"599\" data-end=\"629\"\u003ewater treatment facilities\u003c\/strong\u003e. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"636\" data-end=\"660\"\u003e16 isolated channels\u003c\/strong\u003e, this module facilitates the acquisition of digital signals from various field devices such as switches and sensors.\u003c\/p\u003e\n\u003ch4 data-start=\"779\" data-end=\"798\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-start=\"799\" data-end=\"1664\"\u003e\n\u003cli data-start=\"799\" data-end=\"844\"\u003e\n\u003cp data-start=\"801\" data-end=\"844\"\u003e\u003cstrong data-start=\"801\" data-end=\"810\"\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"812\" data-end=\"842\"\u003eEmerson Ovation 5X00070G01\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"845\" data-end=\"903\"\u003e\n\u003cp data-start=\"847\" data-end=\"903\"\u003e\u003cstrong data-start=\"847\" data-end=\"855\"\u003eType\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"857\" data-end=\"901\"\u003e16-Channel Digital Input (Contact Input)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"991\"\u003e\n\u003cp data-start=\"906\" data-end=\"991\"\u003e\u003cstrong data-start=\"906\" data-end=\"923\"\u003eInput Voltage\u003c\/strong\u003e: Typically\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"935\" data-end=\"945\"\u003e24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"949\" data-end=\"960\"\u003e125V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(depending on configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"992\" data-end=\"1037\"\u003e\n\u003cp data-start=\"994\" data-end=\"1037\"\u003e\u003cstrong data-start=\"994\" data-end=\"1015\"\u003ePower Consumption\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1017\" data-end=\"1025\"\u003e3.5W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(nominal)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1038\" data-end=\"1112\"\u003e\n\u003cp data-start=\"1040\" data-end=\"1112\"\u003e\u003cstrong data-start=\"1040\" data-end=\"1053\"\u003eIsolation\u003c\/strong\u003e: Optical isolation for protection from electrical surges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1113\" data-end=\"1190\"\u003e\n\u003cp data-start=\"1115\" data-end=\"1190\"\u003e\u003cstrong data-start=\"1115\" data-end=\"1127\"\u003eMounting\u003c\/strong\u003e: Easily integrates into standard Ovation\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1169\" data-end=\"1188\"\u003eI\/O branch base\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1191\" data-end=\"1368\"\u003e\n\u003cp data-start=\"1193\" data-end=\"1211\"\u003e\u003cstrong data-start=\"1193\" data-end=\"1208\"\u003eDiagnostics\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1214\" data-end=\"1368\"\u003e\n\u003cli data-start=\"1214\" data-end=\"1252\"\u003e\n\u003cp data-start=\"1216\" data-end=\"1252\"\u003e\u003cstrong data-start=\"1216\" data-end=\"1250\"\u003eIndividual channel status LEDs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1255\" data-end=\"1297\"\u003e\n\u003cp data-start=\"1257\" data-end=\"1297\"\u003e\u003cstrong data-start=\"1257\" data-end=\"1270\"\u003eModule OK\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1275\" data-end=\"1284\"\u003eFault\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1300\" data-end=\"1368\"\u003e\n\u003cp data-start=\"1302\" data-end=\"1368\"\u003e\u003cstrong data-start=\"1302\" data-end=\"1330\"\u003eSequence of Events (SOE)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapability with\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1347\" data-end=\"1366\"\u003e1 ms resolution\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1369\" data-end=\"1439\"\u003e\n\u003cp data-start=\"1371\" data-end=\"1439\"\u003e\u003cstrong data-start=\"1371\" data-end=\"1388\"\u003eHot-Swappable\u003c\/strong\u003e: Can be replaced without interrupting the system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1440\" data-end=\"1529\"\u003e\n\u003cp data-start=\"1442\" data-end=\"1529\"\u003e\u003cstrong data-start=\"1442\" data-end=\"1458\"\u003eConfigurable\u003c\/strong\u003e: Software-selectable filtering to eliminate mechanical switch bounce\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1530\" data-end=\"1664\"\u003e\n\u003cp data-start=\"1532\" data-end=\"1664\"\u003e\u003cstrong data-start=\"1532\" data-end=\"1546\"\u003eRuggedized\u003c\/strong\u003e: Built for environments with high\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1581\" data-end=\"1619\"\u003eelectromagnetic interference (EMI)\u003c\/strong\u003e, like\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1626\" data-end=\"1643\"\u003eturbine decks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"1648\" data-end=\"1664\"\u003eboiler rooms\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1666\" data-end=\"1697\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1698\" data-end=\"2374\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1698\" data-end=\"1772\"\u003e\n\u003ctr data-start=\"1698\" data-end=\"1772\"\u003e\n\u003cth data-start=\"1698\" data-end=\"1732\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"1700\" data-end=\"1717\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1732\" data-end=\"1772\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"1734\" data-end=\"1745\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1849\" data-end=\"2374\"\u003e\n\u003ctr data-start=\"1849\" data-end=\"1923\"\u003e\n\u003ctd data-start=\"1849\" data-end=\"1884\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1851\" data-end=\"1863\"\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1884\" data-end=\"1923\" data-col-size=\"sm\"\u003e16 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1924\" data-end=\"1998\"\u003e\n\u003ctd data-start=\"1924\" data-end=\"1959\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1926\" data-end=\"1943\"\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1959\" data-end=\"1998\" data-col-size=\"sm\"\u003e24V DC or 125V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1999\" data-end=\"2073\"\u003e\n\u003ctd data-start=\"1999\" data-end=\"2034\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2001\" data-end=\"2014\"\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2034\" data-end=\"2073\"\u003eOptical Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2074\" data-end=\"2148\"\u003e\n\u003ctd data-start=\"2074\" data-end=\"2109\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2076\" data-end=\"2097\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2109\" data-end=\"2148\" data-col-size=\"sm\"\u003e3.5W (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2149\" data-end=\"2223\"\u003e\n\u003ctd data-start=\"2149\" data-end=\"2184\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2151\" data-end=\"2163\"\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2184\" data-end=\"2223\" data-col-size=\"sm\"\u003ePlugs into Ovation I\/O Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2224\" data-end=\"2299\"\u003e\n\u003ctd data-start=\"2224\" data-end=\"2259\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2226\" data-end=\"2243\"\u003eHot-Swappable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2259\" data-end=\"2299\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2300\" data-end=\"2374\"\u003e\n\u003ctd data-start=\"2300\" data-end=\"2335\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2302\" data-end=\"2317\"\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"2335\" data-end=\"2374\" data-col-size=\"sm\"\u003eSOE with 1 ms resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sticky h-0 select-none end-(--thread-content-margin) self-end\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cbutton aria-label=\"复制表格\" class=\"hover:bg-token-bg-tertiary text-token-text-secondary my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" class=\"icon\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-lbtco6v1.svg#ce3544\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 data-start=\"2376\" data-end=\"2395\"\u003eApplications\u003c\/h4\u003e\n\u003cp data-start=\"2396\" data-end=\"2697\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2400\" data-end=\"2422\"\u003eOvation 5X00070G01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is ideal for applications requiring robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2473\" data-end=\"2495\"\u003esignal acquisition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2500\" data-end=\"2517\"\u003edigital input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapabilities. It is primarily used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2556\" data-end=\"2587\"\u003epower plant control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2592\" data-end=\"2622\"\u003ewater treatment facilities\u003c\/strong\u003e, offering essential functionality for critical process control operations.\u003c\/p\u003e\n\u003chr data-start=\"2699\" data-end=\"2702\"\u003e\n\u003ch3 data-start=\"2704\" data-end=\"2801\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2708\" data-end=\"2801\"\u003eSiemens 6SL3912-5AP34-0AA0 | Active Interface Module (AIM) for SINAMICS S120 Drive System\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4 data-start=\"2803\" data-end=\"2818\"\u003eOverview\u003c\/h4\u003e\n\u003cp data-start=\"2819\" data-end=\"3234\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2823\" data-end=\"2853\"\u003eSiemens 6SL3912-5AP34-0AA0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2860\" data-end=\"2893\"\u003eActive Interface Module (AIM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2902\" data-end=\"2932\"\u003eSINAMICS S120 drive system\u003c\/strong\u003e. This module is essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2963\" data-end=\"2986\"\u003eline-side filtering\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"2988\" data-end=\"3013\"\u003epre-charging circuits\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3019\" data-end=\"3030\"\u003edamping\u003c\/strong\u003e, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3041\" data-end=\"3069\"\u003eclean power regeneration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein regenerative DC-link systems. It ensures the system can feed braking energy back into the power grid, significantly enhancing energy efficiency during operation.\u003c\/p\u003e\n\u003ch4 data-start=\"3236\" data-end=\"3255\"\u003eKey Features\u003c\/h4\u003e\n\u003cul data-start=\"3256\" data-end=\"3958\"\u003e\n\u003cli data-start=\"3256\" data-end=\"3301\"\u003e\n\u003cp data-start=\"3258\" data-end=\"3301\"\u003e\u003cstrong data-start=\"3258\" data-end=\"3267\"\u003eModel\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3269\" data-end=\"3299\"\u003eSiemens 6SL3912-5AP34-0AA0\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3302\" data-end=\"3349\"\u003e\n\u003cp data-start=\"3304\" data-end=\"3349\"\u003e\u003cstrong data-start=\"3304\" data-end=\"3312\"\u003eType\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3314\" data-end=\"3347\"\u003eActive Interface Module (AIM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3350\" data-end=\"3406\"\u003e\n\u003cp data-start=\"3352\" data-end=\"3406\"\u003e\u003cstrong data-start=\"3352\" data-end=\"3370\"\u003eVoltage Rating\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3372\" data-end=\"3396\"\u003e3-Phase 380–480 V AC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(± 10%)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3407\" data-end=\"3439\"\u003e\n\u003cp data-start=\"3409\" data-end=\"3439\"\u003e\u003cstrong data-start=\"3409\" data-end=\"3426\"\u003eRated Current\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3428\" data-end=\"3437\"\u003e605 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3440\" data-end=\"3485\"\u003e\n\u003cp data-start=\"3442\" data-end=\"3485\"\u003e\u003cstrong data-start=\"3442\" data-end=\"3457\"\u003eRated Power\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3459\" data-end=\"3483\"\u003eApproximately 400 kW\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3486\" data-end=\"3570\"\u003e\n\u003cp data-start=\"3488\" data-end=\"3570\"\u003e\u003cstrong data-start=\"3488\" data-end=\"3511\"\u003eHarmonic Distortion\u003c\/strong\u003e: Reduces\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3521\" data-end=\"3556\"\u003eTotal Harmonic Distortion (THD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3560\" data-end=\"3568\"\u003e\u0026lt; 3%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3571\" data-end=\"3644\"\u003e\n\u003cp data-start=\"3573\" data-end=\"3644\"\u003e\u003cstrong data-start=\"3573\" data-end=\"3584\"\u003eCooling\u003c\/strong\u003e: Internal\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3595\" data-end=\"3610\"\u003eair cooling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(requires adequate ventilation)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3645\" data-end=\"3752\"\u003e\n\u003cp data-start=\"3647\" data-end=\"3752\"\u003e\u003cstrong data-start=\"3647\" data-end=\"3663\"\u003eRegeneration\u003c\/strong\u003e: Enables motor to act as a generator during braking, feeding energy back into the grid\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3753\" data-end=\"3875\"\u003e\n\u003cp data-start=\"3755\" data-end=\"3875\"\u003e\u003cstrong data-start=\"3755\" data-end=\"3779\"\u003ePre-charging Circuit\u003c\/strong\u003e: Integrated components prevent inrush current damage by safely ramping up the DC link voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3876\" data-end=\"3958\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3958\"\u003e\u003cstrong data-start=\"3878\" data-end=\"3899\"\u003eProtection Rating\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"3901\" data-end=\"3909\"\u003eIP00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(open chassis, suitable for cabinet integration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"3960\" data-end=\"3991\"\u003eTechnical Specifications\u003c\/h4\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3992\" data-end=\"4773\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3992\" data-end=\"4066\"\u003e\n\u003ctr data-start=\"3992\" data-end=\"4066\"\u003e\n\u003cth data-start=\"3992\" data-end=\"4026\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"3994\" data-end=\"4011\"\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"4026\" data-end=\"4066\" data-col-size=\"md\" class=\"\"\u003e\u003cstrong data-start=\"4028\" data-end=\"4039\"\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"4143\" data-end=\"4773\"\u003e\n\u003ctr data-start=\"4143\" data-end=\"4217\"\u003e\n\u003ctd data-start=\"4143\" data-end=\"4178\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4145\" data-end=\"4162\"\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4178\" data-end=\"4217\" data-col-size=\"md\"\u003e380–480 V AC (± 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4218\" data-end=\"4293\"\u003e\n\u003ctd data-start=\"4218\" data-end=\"4253\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4220\" data-end=\"4237\"\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4253\" data-end=\"4293\"\u003e605 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4294\" data-end=\"4368\"\u003e\n\u003ctd data-start=\"4294\" data-end=\"4329\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4296\" data-end=\"4311\"\u003eRated Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4329\" data-end=\"4368\"\u003eApproximately 400 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4369\" data-end=\"4443\"\u003e\n\u003ctd data-start=\"4369\" data-end=\"4404\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4371\" data-end=\"4394\"\u003eHarmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4404\" data-end=\"4443\"\u003e\u0026lt; 3% (meets IEEE 519 requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4444\" data-end=\"4518\"\u003e\n\u003ctd data-start=\"4444\" data-end=\"4479\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4446\" data-end=\"4457\"\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4479\" data-end=\"4518\" data-col-size=\"md\"\u003eInternal Air Cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4519\" data-end=\"4593\"\u003e\n\u003ctd data-start=\"4519\" data-end=\"4554\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4521\" data-end=\"4537\"\u003eRegeneration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"4554\" data-end=\"4593\"\u003eYes, energy fed back into the grid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4594\" data-end=\"4684\"\u003e\n\u003ctd data-start=\"4594\" data-end=\"4629\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4596\" data-end=\"4620\"\u003ePre-charging Circuit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4629\" data-end=\"4684\" data-col-size=\"md\"\u003eYes, integrated components for safe voltage ramp-up\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4685\" data-end=\"4773\"\u003e\n\u003ctd data-start=\"4685\" data-end=\"4720\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"4687\" data-end=\"4708\"\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"4720\" data-end=\"4773\" data-col-size=\"md\"\u003eIP00 (open chassis for integration into cabinets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sticky h-0 select-none end-(--thread-content-margin) self-end\"\u003e\n\u003cdiv class=\"absolute end-0 flex items-end\"\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cbutton aria-label=\"复制表格\" class=\"hover:bg-token-bg-tertiary text-token-text-secondary my-1 rounded-sm p-1 transition-opacity group-[:not(:hover):not(:focus-within)]:pointer-events-none group-[:not(:hover):not(:focus-within)]:opacity-0\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" class=\"icon\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-lbtco6v1.svg#ce3544\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/button\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4 data-start=\"4775\" data-end=\"4794\"\u003eApplications\u003c\/h4\u003e\n\u003cp data-start=\"4795\" data-end=\"5186\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"4799\" data-end=\"4829\"\u003eSiemens 6SL3912-5AP34-0AA0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is used in high-power\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"4859\" data-end=\"4890\"\u003eSINAMICS S120 drive systems\u003c\/strong\u003e, where it enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"4909\" data-end=\"4932\"\u003eenergy regeneration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"4937\" data-end=\"4970\"\u003eharmonic distortion reduction\u003c\/strong\u003e. It is ideal for industries that require high-efficiency motor control, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"5051\" data-end=\"5060\"\u003epumps\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"5062\" data-end=\"5070\"\u003efans\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"5072\" data-end=\"5087\"\u003ecompressors\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"5093\" data-end=\"5124\"\u003emotion control applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein sectors like\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"5141\" data-end=\"5158\"\u003emanufacturing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong data-start=\"5163\" data-end=\"5185\"\u003eprocess automation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"5188\" data-end=\"5191\"\u003e\n\u003ch3 data-start=\"5193\" data-end=\"5270\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5197\" data-end=\"5270\"\u003eComparison Summary: Emerson 5X00070G01 vs. Siemens 6SL3912-5AP34-0AA0\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"5272\" data-end=\"6373\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"5272\" data-end=\"5409\"\u003e\n\u003ctr data-start=\"5272\" data-end=\"5409\"\u003e\n\u003cth data-start=\"5272\" data-end=\"5306\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"5274\" data-end=\"5285\"\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"5306\" data-end=\"5359\" data-col-size=\"sm\" class=\"\"\u003e\u003cstrong data-start=\"5308\" data-end=\"5330\"\u003eEmerson 5X00070G01\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"5359\" data-end=\"5409\" data-col-size=\"md\" class=\"\"\u003e\u003cstrong data-start=\"5361\" data-end=\"5391\"\u003eSiemens 6SL3912-5AP34-0AA0\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"5548\" data-end=\"6373\"\u003e\n\u003ctr data-start=\"5548\" data-end=\"5685\"\u003e\n\u003ctd data-start=\"5548\" data-end=\"5583\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5550\" data-end=\"5560\"\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5583\" data-end=\"5636\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5585\" data-end=\"5600\"\u003eOvation DCS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5636\" data-end=\"5685\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"5638\" data-end=\"5668\"\u003eSINAMICS S120 Drive System\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5686\" data-end=\"5823\"\u003e\n\u003ctd data-start=\"5686\" data-end=\"5721\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5688\" data-end=\"5704\"\u003ePrimary Role\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5721\" data-end=\"5774\" data-col-size=\"sm\"\u003eSignal Acquisition (Digital Input)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5774\" data-end=\"5823\"\u003ePower Filtering \u0026amp; Regeneration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5824\" data-end=\"5961\"\u003e\n\u003ctd data-start=\"5824\" data-end=\"5859\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5826\" data-end=\"5844\"\u003eVoltage Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"5859\" data-end=\"5912\"\u003eLow Voltage (24V–125V DC)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"5912\" data-end=\"5961\"\u003eHigh Voltage (380–480 V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"5962\" data-end=\"6099\"\u003e\n\u003ctd data-start=\"5962\" data-end=\"5997\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"5964\" data-end=\"5980\"\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"5997\" data-end=\"6050\" data-col-size=\"sm\"\u003eI\/O Rack \/ Base\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6050\" data-end=\"6099\"\u003ePower Cabinet (Chassis Format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6100\" data-end=\"6235\"\u003e\n\u003ctd data-start=\"6100\" data-end=\"6135\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6102\" data-end=\"6123\"\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6135\" data-end=\"6187\" data-col-size=\"sm\"\u003e3.5 W (Nominal)\u003c\/td\u003e\n\u003ctd data-start=\"6187\" data-end=\"6235\" data-col-size=\"md\"\u003eRequires external cooling and ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"6236\" data-end=\"6373\"\u003e\n\u003ctd data-start=\"6236\" data-end=\"6271\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"6238\" data-end=\"6261\"\u003eHarmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"6271\" data-end=\"6324\" data-col-size=\"sm\"\u003eNot Applicable\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"6324\" data-end=\"6373\"\u003e\u0026lt; 3% (Meets IEEE 519)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Ovation","offers":[{"title":"Default Title","offer_id":44092572696675,"sku":"5X00070G01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/5X00070G01-1.jpg?v=1774947353","url":"https:\/\/precisemodule.com\/products\/emerson-ovation-5x00070g01-16-channel-digital-input-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}