{"product_id":"ge-ds2020dacag2-mark-v-power-conversion-module-ac-dc","title":"GE DS2020DACAG2 Mark V Power Conversion Module AC\/DC","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS2020DACAG2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance AC-to-DC power conversion module designed for the GE Speedtronic Mark V turbine control system. This rugged module delivers stable DC power to critical turbine components, including excitation systems, control logic, and auxiliary devices. Engineered for utility-scale and industrial applications, it ensures precise voltage regulation, robust protection, and high reliability in demanding operational environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Regulation and Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains precise output voltage to ensure accurate control card operation and processor timing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated EMI filtering and electrical isolation protect sensitive components from voltage spikes and noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in overvoltage and overcurrent protection prevents damage to the control backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThermal and Mechanical Reliability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePassive heatsink design ensures efficient thermal management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRated for continuous operation in ambient temperatures from -30°C to +65°C with non-condensing humidity 5–95%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade components provide high MTBF for minimal downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with GE Mark V gas and steam turbine control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides diagnostic feedback signals for power health monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard Mark V form factor enables seamless panel\/rack installation with secure mounting brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy and Operational Flexibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports parallel operation for higher output or redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures uninterrupted operation during module replacement or maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField excitation for generator units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary DC power supply in turbine control racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy Mark V system upgrades and life-extension projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGE Speedtronic Mark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eAC-to-DC Power Conversion \/ Excitation Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e115–230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePanel or floor mount using brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCooling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePassive (Heatsink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eIndustrial-grade, vibration-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the DS2020DACAG2?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS2020DACAG2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a regulated AC-to-DC power module providing 125 VDC output for Mark V turbine systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DS2020DACAG2 replace previous versions?\u003c\/strong\u003e\u003cbr\u003eYes, it is backward compatible with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS2020DACAG1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand offers higher power output for parallel operation or redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat environments is this module suited for?\u003c\/strong\u003e\u003cbr\u003eIt is intended for non-corrosive, non-combustible environments with controlled temperature and humidity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module mounted?\u003c\/strong\u003e\u003cbr\u003eIt can be panel-mounted or securely installed in the floor of a turbine control cabinet using the provided brackets and bolts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module perform diagnostics?\u003c\/strong\u003e\u003cbr\u003eNo, monitoring of input\/output levels and health status is managed by the main turbine control system.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44133850349667,"sku":"DS2020DACAG2","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/GEDS2020DACAG2-3.jpg?v=1776851068","url":"https:\/\/precisemodule.com\/products\/ge-ds2020dacag2-mark-v-power-conversion-module-ac-dc","provider":"Precise Module Ltd.","version":"1.0","type":"link"}