{"product_id":"ge-fanuc-469-p1-hi-a20-motor","title":"GE Fanuc|469-P1-HI-A20|Motor","description":"\u003ch4 class=\"qk-md-head\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eProduct Overview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qk-md-strong complete\"\u003eGE Fanuc 469-P1-HI-A20\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e is a sophisticated digital relay belonging to the renowned Multilin™ 469 series. It is engineered to provide comprehensive protection, control, and monitoring for medium and large-sized industrial motors. This relay integrates advanced thermal modeling with precise metering capabilities to ensure the longevity and reliability of critical motor assets.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eDesigned for versatility, the \u003c\/span\u003e\u003cspan class=\"qk-md-strong complete\"\u003e469-P1-HI-A20\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e features a robust drawout case design, allowing for rapid replacement and maintenance without disturbing field wiring. It combines high-speed protection algorithms with extensive communication options, making it a central component in modern industrial automation and power management systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 class=\"qk-md-head\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eKey Features \u0026amp; Benefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"qk-md-ul list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eAdvanced Thermal Protection:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Utilizes a dynamic thermal model that accounts for thermal capacity used, negative sequence current (unbalance), and RTD inputs to accurately track motor heating and cooling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eDrawout Architecture:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e The unit is housed in a drawout case, facilitating easy removal and installation for maintenance or replacement, minimizing system downtime.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eHigh-Precision Metering:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Provides accurate real-time monitoring of current, voltage, and power parameters, with four scalable 4-20 mA analog outputs for integration with external control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eComprehensive Fault Recording:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Capable of storing waveform data (up to 16 cycles) during trip events, aiding in rapid fault diagnosis and root cause analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eFlexible Communication:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Equipped with RS232 and RS485 ports supporting open protocols (Modbus), allowing for seamless integration into SCADA and DCS networks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eVersatile Control Power:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Supports a wide range of AC and DC control power inputs, ensuring compatibility with various industrial power distribution schemes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"qk-md-head\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-table-action-title\"\u003e表格\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"qk-md-table\" width=\"478\"\u003e\n\u003cthead class=\"qk-md-table-head\"\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan class=\"qk-md-text complete\"\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan class=\"qk-md-text complete\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"qk-md-table-body\"\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003e469-P1-HI-A20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003eGE Fanuc \/ GE Multilin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003eMotor Management Relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003ePhase CT Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e1 A Secondaries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eControl Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e90-300 V DC \/ 70-265 V AC (48-62 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eAnalog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e4 x 4-20 mA (±1% accuracy, 1200 Ω max load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eDifferential CT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e1-5000 A Primary (1A\/5A Secondary)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eGround CT\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e1-5000 A Primary (±0.125 A accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eRTD Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e12 Inputs (for stator\/bearing temperature)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e4.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"qk-md-table-row\"\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-strong\"\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"qk-md-text complete\"\u003e40-character Vacuum Fluorescent Display\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 class=\"qk-md-head\"\u003e\u003cspan class=\"qk-md-text complete\"\u003eProtection \u0026amp; Monitoring Capabilities\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-text complete\"\u003eThe \u003c\/span\u003e\u003cspan class=\"qk-md-strong complete\"\u003e469-P1-HI-A20\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e offers a suite of protective functions designed to prevent motor damage:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"qk-md-ul list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eThermal Overload:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Mimics the motor's heating characteristics to prevent insulation failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eStall \u0026amp; Jam Protection:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Detects locked rotor conditions during start or run modes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eGround Fault:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e High-sensitivity detection for insulation breakdown.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003ePhase Unbalance:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Protects against negative sequence currents that cause rotor overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"qk-md-strong complete\"\u003eShort Circuit:\u003c\/span\u003e\u003cspan class=\"qk-md-text complete\"\u003e Fast-acting trip for high-current faults.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44083706331235,"sku":"469-P1-HI-A20","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/21a59292b704f25dc9bce363428d09f5.png?v=1774597263","url":"https:\/\/precisemodule.com\/products\/ge-fanuc-469-p1-hi-a20-motor","provider":"Precise Module Ltd.","version":"1.0","type":"link"}