{"product_id":"ge-is200tturh1cfd-turbine-terminal-board-mark-vie-speed-shaft-monitoring","title":"GE IS200TTURH1CFD | Turbine Terminal Board | Mark VIe | Speed \u0026 Shaft Monitoring","description":"\u003ch3\u003e\u003cspan\u003eProduct Description\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eGE IS200TTURH1CFD\u003c\/span\u003e is a high-performance \u003cspan\u003eTurbine Terminal Board\u003c\/span\u003e designed for integration with the \u003cspan\u003eMark VIe Control System\u003c\/span\u003e. This terminal board serves as the interface for critical turbine signals such as speed sensing, synchronization, and shaft voltage monitoring. When paired with the \u003cspan\u003eIS230TNTRH1C I\/O Pack\u003c\/span\u003e, the board converts analog turbine data into digital signals, enabling seamless communication with the Mark VIe controller.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eKey Technical Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal Inputs\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e is engineered to handle high-precision turbine data, ensuring accurate monitoring and control:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePassive Speed Inputs\u003c\/span\u003e: Accepts signals from magnetic pickups for measuring turbine RPM.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eActive Speed Inputs\u003c\/span\u003e: Interfaces with active proximity probes for enhanced speed monitoring accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGenerator Voltage\/Frequency\u003c\/span\u003e: Monitors the generator and bus voltage to ensure synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShaft Voltage\/Current Monitoring\u003c\/span\u003e: Includes specialized circuits to monitor shaft grounding and potential electrical discharge, preventing damage to turbine bearings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhysical Design \u0026amp; Mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eForm Factor\u003c\/span\u003e: Available in double-width or standard vertical terminal block configuration to fit various cabinet designs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTermination\u003c\/span\u003e: Two sets of 24 screw terminals for easy and secure field wiring connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eI\/O Pack Compatibility\u003c\/span\u003e: Compatible with the \u003cspan\u003eIS230TNTRH1C\u003c\/span\u003e or \u003cspan\u003eIS200TNTR\u003c\/span\u003e series I\/O packs, connecting via \u003cspan\u003eD-type connectors\u003c\/span\u003e for efficient digital signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHardware Features\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e includes several features to ensure reliable operation in industrial environments:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e: Supports \u003cspan\u003eSimplex\u003c\/span\u003e, \u003cspan\u003eDual\u003c\/span\u003e, or \u003cspan\u003eTMR (Triple Modular Redundant)\u003c\/span\u003e configurations for increased system reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFiltering\u003c\/span\u003e: Built-in high-frequency noise filters and surge protection to maintain signal integrity in noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCold End Compensation\u003c\/span\u003e: Useful for applications involving thermocouple signals routed through specific turbine boards (though primarily focused on speed and synchronization).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eModule Comparison: IS200TTURH1CFD vs IS230TNTRH1C\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIS200TTURH1CFD (Terminal Board)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIS230TNTRH1C (I\/O Pack)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrimary Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal termination \u0026amp; conditioning\u003c\/td\u003e\n\u003ctd\u003eSignal digitization \u0026amp; Ethernet communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponents\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, resistors, capacitors, MOV protection\u003c\/td\u003e\n\u003ctd\u003eMicroprocessors, A\/D converters, Ionet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaintenance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive component, low failure rate\u003c\/td\u003e\n\u003ctd\u003eActive component, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog signals (speed, voltage, shaft)\u003c\/td\u003e\n\u003ctd\u003eDigital signals (converted via I\/O pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eEnvironmental \u0026amp; Operating Limits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e is designed to operate in demanding industrial environments. It can withstand a wide range of conditions typically found in power plants and other industrial facilities.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHumidity\u003c\/span\u003e: 5% to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e: Meets seismic and operational vibration resistance standards as specified by \u003cspan\u003eGE Mark VIe\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConformal Coating\u003c\/span\u003e: The \u003cspan\u003eCFD\u003c\/span\u003e suffix indicates that the board is treated with a special \u003cspan\u003econformal coating\u003c\/span\u003e for enhanced protection against moisture, dust, and corrosive chemicals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e is ideal for \u003cspan\u003egas and steam turbine power generation\u003c\/span\u003e systems. It is used extensively in environments that require precise monitoring and control of turbine parameters, such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGas Turbine Power Plants\u003c\/span\u003e: Ensures safe and efficient turbine operation by accurately measuring speed, shaft voltage, and synchronizing the generator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSteam Turbine Systems\u003c\/span\u003e: Used for speed sensing, shaft monitoring, and generator synchronization to optimize performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTurbine Protection Systems\u003c\/span\u003e: The \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e ensures the turbine operates within safe parameters, preventing mechanical failure and damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eMaintenance and Handling Tips\u003c\/span\u003e\u003c\/h4\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eESD Sensitivity\u003c\/span\u003e: Handle the \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e carefully as it contains sensitive electronic components. Always use an \u003cspan\u003eanti-static wrist strap\u003c\/span\u003e when working with the unit to avoid damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisual Inspection\u003c\/span\u003e: Regularly inspect the board for signs of wear, such as discoloration of components or damage to the terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFirmware Compatibility\u003c\/span\u003e: Ensure that the \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e is used in conjunction with the compatible \u003cspan\u003eIS230TNTRH1C\u003c\/span\u003e or \u003cspan\u003eIS200TNTR\u003c\/span\u003e I\/O packs to ensure correct data processing and communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConformal Coating Maintenance\u003c\/span\u003e: Check the condition of the \u003cspan\u003econformal coating\u003c\/span\u003e periodically, as it protects the board from corrosion and damage in harsh industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eFAQs\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the role of the IS200TTURH1CFD in turbine control?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA:\u003c\/span\u003e The \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e acts as a termination point for critical turbine signals, such as speed, shaft voltage, and synchronization data. It ensures that these analog signals are converted into digital signals for processing by the \u003cspan\u003eMark VIe Control System\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can the IS200TTURH1CFD board be used in a redundant configuration?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA:\u003c\/span\u003e Yes, the \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e supports \u003cspan\u003eSimplex\u003c\/span\u003e, \u003cspan\u003eDual\u003c\/span\u003e, and \u003cspan\u003eTMR (Triple Modular Redundant)\u003c\/span\u003e configurations, which increases system reliability by ensuring turbine operation continues safely even if one processor fails.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What is the difference between the IS200TTURH1CFD and the IS230TNTRH1C?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA:\u003c\/span\u003e The \u003cspan\u003eIS200TTURH1CFD\u003c\/span\u003e is a \u003cspan\u003eTurbine Terminal Board\u003c\/span\u003e that handles signal termination and conditioning, while the \u003cspan\u003eIS230TNTRH1C\u003c\/span\u003e is an \u003cspan\u003eI\/O pack\u003c\/span\u003e that digitizes and processes these signals for communication with the \u003cspan\u003eMark VIe Control System\u003c\/span\u003e.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44092467806307,"sku":"IS220PTURH1B（IS230TNTRH1C）","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/IS220PTURH1B_IS230TNTRH1C_-1.jpg?v=1774940364","url":"https:\/\/precisemodule.com\/products\/ge-is200tturh1cfd-turbine-terminal-board-mark-vie-speed-shaft-monitoring","provider":"Precise Module Ltd.","version":"1.0","type":"link"}