{"product_id":"ge-is200vaich1daa-mark-vi-analog-input-output-board-vaic-module","title":"GE IS200VAICH1DAA Mark VI Analog Input\/Output Board | VAIC Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS200VAICH1DAA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density Analog Input\/Output (I\/O) board designed for the Mark VI Speedtronic system. This VAIC board provides a reliable interface between field sensors and the VME-based control rack, delivering precise and high-speed analog signal acquisition for gas and steam turbine monitoring and control. It supports both current and voltage signals, making it adaptable to a wide range of industrial transmitters.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eGE Mark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VAICH1DAA (VAIC Analog I\/O Board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Differential\/Single-Ended Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-1 mA, ±5 V, ±10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Drive\u003c\/td\u003e\n\u003ctd\u003eSupports up to 18 V at screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eVME-bus (6U height)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Board Compatibility\u003c\/td\u003e\n\u003ctd\u003eTBAX, TFAI, TBCI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSimplex, Dual, and Triple Modular Redundant (TMR) capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eBuilt-In Test Equipment (BITE) with multiple checks for signal integrity and hardware faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003eHigh-speed sampling synchronized with Mark VI controller cores\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation with EMI\/RFI filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eVME Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003ePerformance Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Signal Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel can be individually configured via software for voltage or current input, allowing integration with a variety of sensors measuring pressure, flow, temperature, or level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e14- to 16-bit A\/D converters ensure precise measurement of small signal variations for accurate turbine control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapable of sampling all channels at high speed to meet the demands of critical turbine monitoring applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFault-Tolerant Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFully supports TMR architectures, ensuring the highest level of reliability in safety-critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eContinuous monitoring detects open circuits, out-of-range signals, and internal faults, with status reported to the control system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust isolation protects the VME bus from electrical surges and electromagnetic interference from turbine hall environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFuel, lube oil, and compressor discharge pressures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Measurement:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFuel and cooling water flows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eValve Position Tracking:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfaces with LVDTs\/RVDTs for servo-valve position feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLevel Sensing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors tanks for water-wash and oil-sump systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board operate in both simplex and TMR configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the IS200VAICH1DAA supports simplex, dual, and triple modular redundant configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do I ensure compatibility when replacing the board?\u003c\/strong\u003e\u003cbr\u003eA: Verify firmware version compatibility and configure jumpers\/DIP switches to match the previous setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of signals can the board accept?\u003c\/strong\u003e\u003cbr\u003eA: The board supports 4-20 mA current loops, 0-1 mA, ±5 V, and ±10 V voltage inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this board drive high-load analog outputs?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports higher load resistances with up to 18 V at the terminal board.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44132993597539,"sku":"IS200VAICH1DAA","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/GEIS200VAICH1DAA-3.jpg?v=1776822529","url":"https:\/\/precisemodule.com\/products\/ge-is200vaich1daa-mark-vi-analog-input-output-board-vaic-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}