{"product_id":"ge-is220paich1bg-analog-input-i-o-pack-high-performance-signal-processing","title":"GE IS220PAICH1BG | Analog Input I\/O Pack | High-Performance Signal Processing","description":"\u003ch4\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eGE IS220PAICH1BG\u003c\/span\u003e is an advanced \u003cspan\u003eAnalog Input I\/O Pack\u003c\/span\u003e designed for use in the \u003cspan\u003eMark VIe\u003c\/span\u003e control system. This high-performance module provides the capability to process and digitize \u003cspan\u003edifferential analog signals\u003c\/span\u003e with \u003cspan\u003eenhanced diagnostics\u003c\/span\u003e. It offers \u003cspan\u003e10 input channels\u003c\/span\u003e and integrates seamlessly with the \u003cspan\u003eIS230SNAIH2A Simplex Analog Input Terminal Board\u003c\/span\u003e. The \u003cspan\u003eBG\u003c\/span\u003e revision features conformal coating, offering protection against harsh industrial environments, ensuring the pack's longevity and reliability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eKey Features and Specifications\u003c\/span\u003e\u003c\/h4\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInput Capabilities\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Inputs\u003c\/span\u003e: \u003cspan\u003e0–20 mA\u003c\/span\u003e or \u003cspan\u003e4–20 mA\u003c\/span\u003e (using 250 Ω precision resistors).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVoltage Inputs\u003c\/span\u003e: \u003cspan\u003e±5 V\u003c\/span\u003e or \u003cspan\u003e±10 V DC\u003c\/span\u003e for versatile signal measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e: \u003cspan\u003e10 Differential Analog Inputs\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInput Ranges\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransmitter Power\u003c\/span\u003e: Supplies \u003cspan\u003e24 VDC\u003c\/span\u003e to field transmitters across all \u003cspan\u003e10 channels\u003c\/span\u003e (fused on the connected terminal board).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePerformance \u0026amp; Conversion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eA\/D Conversion\u003c\/span\u003e: \u003cspan\u003e16-bit resolution\u003c\/span\u003e ensures precise signal digitization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e: \u003cspan\u003e±0.1%\u003c\/span\u003e of full-scale input range at room temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSampling Rate\u003c\/span\u003e: Supports fast data acquisition, typically at \u003cspan\u003e10 ms\u003c\/span\u003e or \u003cspan\u003e40 ms\u003c\/span\u003e frame rates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommon Mode Rejection\u003c\/span\u003e: \u003cspan\u003e\u0026gt; 80 dB\u003c\/span\u003e at \u003cspan\u003e60 Hz\u003c\/span\u003e, ensuring stable operation even in noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcessor \u0026amp; Communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProcessor\u003c\/span\u003e: Local \u003cspan\u003eBPPx\u003c\/span\u003e processor handles signal scaling, diagnostics, and real-time data conversion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNetwork\u003c\/span\u003e: Dual \u003cspan\u003e100BASE-TX RJ-45 Ethernet ports\u003c\/span\u003e for \u003cspan\u003eredundant Ionet connectivity\u003c\/span\u003e, ensuring reliable communication with the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLED Indicators\u003c\/span\u003e: The I\/O pack features \u003cspan\u003estatus LEDs\u003c\/span\u003e for monitoring \u003cspan\u003ePower\u003c\/span\u003e, \u003cspan\u003eLink\u003c\/span\u003e, \u003cspan\u003eEthernet Traffic\u003c\/span\u003e, and \u003cspan\u003eDiagnostic Faults\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDiagnostics \u0026amp; Maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCurrent Loop Verification\u003c\/span\u003e: Detects wire breaks or sensor failures by reading the actual loop current.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransmitter Power Monitoring\u003c\/span\u003e: Alerts the system if the \u003cspan\u003e24 VDC power fuse\u003c\/span\u003e is blown, ensuring field transmitters operate correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHardware Limit Checks\u003c\/span\u003e: Monitors internal power supplies and temperatures to protect the system from malfunctions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfiguration Verification\u003c\/span\u003e: Compares the \u003cspan\u003eBoard ID\u003c\/span\u003e from the \u003cspan\u003eIS230SNAIH2A\u003c\/span\u003e assembly with the system’s settings, preventing configuration mismatches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eComparison: IS220PAICH1BG vs. IS230SNAIH2A\u003c\/span\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIS220PAICH1BG (I\/O Pack)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eIS230SNAIH2A (Assembly)\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePrimary Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eSignal processing \u0026amp; A\/D conversion.\u003c\/td\u003e\n\u003ctd\u003ePhysical termination \u0026amp; signal conditioning.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eDual \u003cspan\u003eIonet\u003c\/span\u003e ports for network redundancy.\u003c\/td\u003e\n\u003ctd\u003eSimplex configuration (single pack interface).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaintenance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHot-swappable active module.\u003c\/td\u003e\n\u003ctd\u003ePassive base; requires shutdown for replacement.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal electronic limits.\u003c\/td\u003e\n\u003ctd\u003eOn-board \u003cspan\u003eMOVs\u003c\/span\u003e and \u003cspan\u003e24V transmitter fuses\u003c\/span\u003e.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eEnvironmental \u0026amp; Operational Ratings\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e: \u003cspan\u003e-30°C to +65°C\u003c\/span\u003e (—22°F to +149°F), making it suitable for use in various industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHumidity\u003c\/span\u003e: Operates effectively within \u003cspan\u003e5% to 95%\u003c\/span\u003e non-condensing humidity levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCoating\u003c\/span\u003e: The \u003cspan\u003eBG\u003c\/span\u003e revision is \u003cspan\u003econformal coated\u003c\/span\u003e, providing enhanced protection against moisture, chemical exposure, and environmental contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHazardous Locations\u003c\/span\u003e: \u003cspan\u003eClass I, Division 2\u003c\/span\u003e rated, suitable for hazardous environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003eThe \u003cspan\u003eIS220PAICH1BG\u003c\/span\u003e is designed for use in applications where high-density analog signal acquisition and processing are needed, particularly in \u003cspan\u003eindustrial automation\u003c\/span\u003e systems such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eField Data Acquisition\u003c\/span\u003e: Interfaces with \u003cspan\u003esensors\u003c\/span\u003e such as \u003cspan\u003epressure\u003c\/span\u003e, \u003cspan\u003etemperature\u003c\/span\u003e, and \u003cspan\u003eflow meters\u003c\/span\u003e in control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem Integration\u003c\/span\u003e: Provides precise, fast, and reliable signal conversion for applications with complex automation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower Plant Control Systems\u003c\/span\u003e: Ensures accurate monitoring of key industrial processes by converting analog signals for controller input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch4\u003e\u003cspan\u003eFAQ\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003eQ: What types of signals can the IS220PAICH1BG process?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA\u003c\/span\u003e: The \u003cspan\u003eIS220PAICH1BG\u003c\/span\u003e processes both \u003cspan\u003ecurrent\u003c\/span\u003e (0–20 mA, 4–20 mA) and \u003cspan\u003evoltage\u003c\/span\u003e (±5 V, ±10 V DC) signals, making it ideal for a variety of field sensors and transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: How does the IS220PAICH1BG ensure signal reliability?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA\u003c\/span\u003e: The module features \u003cspan\u003e16-bit A\/D conversion\u003c\/span\u003e, \u003cspan\u003ecommon mode rejection\u003c\/span\u003e greater than \u003cspan\u003e80 dB\u003c\/span\u003e at \u003cspan\u003e60 Hz\u003c\/span\u003e, and advanced diagnostics like \u003cspan\u003ecurrent loop verification\u003c\/span\u003e to ensure high signal accuracy and system integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: Can this I\/O pack be used in a redundant configuration?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA\u003c\/span\u003e: The \u003cspan\u003eIS220PAICH1BG\u003c\/span\u003e supports \u003cspan\u003edual Ethernet ports\u003c\/span\u003e for \u003cspan\u003eredundant Ionet connectivity\u003c\/span\u003e, providing network redundancy. However, the associated \u003cspan\u003eIS230SNAIH2A\u003c\/span\u003e assembly is a \u003cspan\u003esimplex\u003c\/span\u003e configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eQ: What kind of protection is provided for the field wiring?\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eA\u003c\/span\u003e: The system includes \u003cspan\u003eMOVs\u003c\/span\u003e for surge protection and \u003cspan\u003efuses\u003c\/span\u003e for \u003cspan\u003e24V transmitter power\u003c\/span\u003e, ensuring the system remains operational even in the presence of electrical faults.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44092545138787,"sku":"IS220PAICH1BG（IS230SNAIH2A）","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/IS220PAICH1BG_IS230SNAIH2A_-1.jpg?v=1774943709","url":"https:\/\/precisemodule.com\/products\/ge-is220paich1bg-analog-input-i-o-pack-high-performance-signal-processing","provider":"Precise Module Ltd.","version":"1.0","type":"link"}