{"product_id":"ge-mark-v-ds200siobh1aba-serial-i-o-control-board-speedtronic","title":"GE Mark V DS200SIOBH1ABA Serial I\/O Control Board | Speedtronic","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200SIOBH1ABA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom General Electric is a specialized Serial Input\/Output (I\/O) board within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark V Speedtronic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eturbine control family. Designed for gas and steam turbine control applications, it provides a high-reliability communication interface, connecting the control processors to field devices, monitoring equipment, and peripheral systems. The board ensures precise signal handling and robust data exchange critical to maintaining turbine efficiency and safety.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Communication Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles multiple serial channels for RS-232\/RS-485 interfaces, enabling seamless connection to HMIs, printers, and remote terminal units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-Board Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated microprocessors execute communication tasks independently, reducing the load on the main Mark V cores.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic LEDs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel indicators provide real-time status for power, signal transmission, and fault detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eJumper \u0026amp; Switch Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with twenty jumpers and three switch blocks (six switches each), factory-set for optimal system compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrostatic Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for safe handling during installation and replacement, with static-safe packaging recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReliable System Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures compatibility with Mark V firmware and maintains consistent operational behavior when replacing boards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDS200SIOBH1ABA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMark V Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBoard Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSerial Input\/Output (I\/O) Control Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40-pin J-port ribbon connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitches \u0026amp; Jumpers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 Jumpers, 3 Switch Blocks with 6 switches each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle LED for operational diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in card compatible with Mark V rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower plant control cabinets, industrial-grade reliability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurbine Control Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides critical communication links between turbine cores and peripheral monitoring devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePeripheral Device Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnects the Mark V system to printers, data loggers, and external acquisition devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Routing Across Cores:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFacilitates consistent data exchange between multiple Mark V modules for synchronized turbine operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How should the DS200SIOBH1ABA board be replaced?\u003c\/strong\u003e\u003cbr\u003eA: Match the jumper and switch positions of the old board when installing the replacement to maintain consistent operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the board support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eA: No, replacement should be performed with the system powered down, following ESD precautions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Where can I source this board?\u003c\/strong\u003e\u003cbr\u003eA: World of Controls provides new, rebuilt, and repair services for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200SIOBH1ABA\u003c\/strong\u003e, backed by a warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there similar Mark V boards?\u003c\/strong\u003e\u003cbr\u003eA: Other Mark V I\/O boards include DS200SIOBH1AA and DS200SIOBH1AC, which offer variations in I\/O channel counts and switch configurations.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":44144211034211,"sku":"DS200SIOBH1ABA","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/GEDS200SIOBH1ABA.jpg?v=1777283775","url":"https:\/\/precisemodule.com\/products\/ge-mark-v-ds200siobh1aba-serial-i-o-control-board-speedtronic","provider":"Precise Module Ltd.","version":"1.0","type":"link"}