{"product_id":"hima-f3313-4-channel-high-side-signal-filter-module-for-planar4-safety-systems","title":"HIMA F3313 4-Channel High-Side Signal Filter Module for Planar4 Safety Systems","description":"\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Description:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHIMA F3313\u003c\/span\u003e is a \u003cspan\u003e4-channel High-Side Signal Filter Module\u003c\/span\u003e designed for use in the \u003cspan\u003eHIMA Planar4\u003c\/span\u003e system, a \u003cspan\u003elegacy\u003c\/span\u003e safety platform renowned for its \u003cspan\u003ehardwired reliability\u003c\/span\u003e and \u003cspan\u003ehigh-integrity interlocking\u003c\/span\u003e. Unlike programmable modules in newer systems (like the H41q\/H51q), the F3313 is a \u003cspan\u003enon-programmable, hardware-based signal conditioner\u003c\/span\u003e, ideal for high-speed, safety-critical environments where \u003cspan\u003ephysical hardwiring\u003c\/span\u003e is paramount.\u003c\/p\u003e\n\u003cp\u003eThis module filters and stabilizes input signals from field devices such as \u003cspan\u003epressure switches\u003c\/span\u003e, \u003cspan\u003eemergency stop buttons\u003c\/span\u003e, or other digital signals, ensuring high-frequency noise rejection. By removing unwanted EMI (electromagnetic interference) or contact bounce, the F3313 ensures that only clean, stable signals reach the logic system for processing. With its \u003cspan\u003ehigh-side switching\u003c\/span\u003e, this module operates on the \u003cspan\u003epositive leg of a 24 VDC circuit\u003c\/span\u003e, further enhancing signal integrity and safety.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHardwired Safety Logic:\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eNo software or microprocessor\u003c\/span\u003e involved—reliability is achieved through physical wiring on the backplane, ensuring the highest level of safety and speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignal Filtering:\u003c\/span\u003e\u003cbr\u003eSpecifically designed to remove unwanted noise, including \u003cspan\u003econtact bounce\u003c\/span\u003e and \u003cspan\u003eEMI\u003c\/span\u003e, ensuring that only clean and reliable signals are sent to the safety logic system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Side Switching:\u003c\/span\u003e\u003cbr\u003eThe F3313 switches or monitors the \u003cspan\u003epositive leg (L+)\u003c\/span\u003e of a 24 VDC circuit, making it suitable for a wide range of industrial control and safety applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety Class:\u003c\/span\u003e\u003cbr\u003eCapable of integration into systems rated up to \u003cspan\u003eSIL 4\u003c\/span\u003e, depending on the overall architecture of the \u003cspan\u003ePlanar4\u003c\/span\u003e system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePlug-and-Play Installation:\u003c\/span\u003e\u003cbr\u003eEasily installed as a \u003cspan\u003eplug-in card\u003c\/span\u003e into the \u003cspan\u003eHIMA Planar4 subrack\u003c\/span\u003e, with no need for programming or configuration, reducing downtime and simplifying maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15% to +20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 8 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitching Threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eON: \u0026gt; 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDelay\/Filter Time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 1 ms to 10 ms (Hardware fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eActive logic signal (Internal HIMA Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eForm Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003ePlug-in card for \u003cspan\u003eHIMA Planar4\u003c\/span\u003e subrack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eFunctional Logic:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eF3313\u003c\/span\u003e serves as the \"front door\" for \u003cspan\u003edigital signals\u003c\/span\u003e in the \u003cspan\u003eHIMA Planar4\u003c\/span\u003e system, specifically conditioning and filtering signals from \u003cspan\u003efield devices\u003c\/span\u003e (e.g., \u003cspan\u003epressure switches\u003c\/span\u003e or \u003cspan\u003eE-Stop buttons\u003c\/span\u003e) before they are processed by safety logic modules. After filtering out noise and unwanted spikes, the module transmits the stabilized signal to internal \u003cspan\u003elogic modules\u003c\/span\u003e (like the \u003cspan\u003eF32xx series AND\/OR gates\u003c\/span\u003e), which then perform the required safety actions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eMaintenance and Replacement:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo Programming Required:\u003c\/span\u003e\u003cbr\u003eThe \u003cspan\u003eF3313\u003c\/span\u003e operates purely as a hardwired component, meaning it does not require any configuration changes when replaced. If the module fails, it can be swapped out with a spare without needing software updates or IP reconfigurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePhysical Wiring Considerations:\u003c\/span\u003e\u003cbr\u003eBecause the \u003cspan\u003ePlanar4 system\u003c\/span\u003e is hardwired, \u003cspan\u003eany changes\u003c\/span\u003e to the safety logic (e.g., module replacements or adjustments) necessitate \u003cspan\u003ephysical rewiring\u003c\/span\u003e and a \u003cspan\u003efull re-validation\u003c\/span\u003e of the safety loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePin Alignment:\u003c\/span\u003e\u003cbr\u003eThe connectors in the \u003cspan\u003ePlanar4 subrack\u003c\/span\u003e are \u003cspan\u003efine-pinned\u003c\/span\u003e, so care must be taken during installation to prevent damage to the pins. Forcing the module into the subrack can cause pin damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLED Status Indicators:\u003c\/span\u003e\u003cbr\u003eEach channel typically has a small LED to indicate whether the input signal is \"High\" (active). If the LED is off, but 24 VDC is still present at the terminal, it suggests a failure in the \u003cspan\u003einternal filter\u003c\/span\u003e or \u003cspan\u003eopto-coupler\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":44096125993059,"sku":"F3313","price":180.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/precisemodule.com\/products\/hima-f3313-4-channel-high-side-signal-filter-module-for-planar4-safety-systems","provider":"Precise Module Ltd.","version":"1.0","type":"link"}