{"product_id":"honeywell-05704-a-0144-four-channel-control-card","title":"Honeywell 05704-A-0144 Four-Channel Control Card","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 05704-A-0144\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance, four-channel control card designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem 57\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egas detection architecture. This module serves as the central processing hub for up to four independent gas sensors, providing a robust and scalable solution for industrial safety and environmental monitoring. Engineered to interface with both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecatalytic bead sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20mA analog transmitters\u003c\/strong\u003e, it ensures precise detection of combustible gases, toxic gases, or oxygen depletion.\u003c\/p\u003e\n\u003cp\u003eEach channel on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e05704-A-0144\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a clear, backlit display that provides real-time gas concentrations and alarm status at a glance. The card is equipped with programmable relay outputs for automated safety actions and offers highly granular sensor drive adjustments (90 to 315 mA) to optimize the performance of various sensing technologies. With integrated short-circuit and open-circuit protection, this USA-made control card is a mission-critical component for maintaining safety in refineries, chemical plants, and manufacturing facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell (Analytics)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e05704-A-0144\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem 57\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour-Channel Control Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* Catalytic Bead Sensors (Bridge-type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA Analog Signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Drive:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConstant current\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustment Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e90 to 315 mA (in 1 mA electronic steps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Drive Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 mV to 300 mV (Full scale)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInitial Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"math-inline\"\u003e$\\pm$\u003c\/span\u003e1%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBridge Balance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eElectronic adjustment for bridge balance and signal gain\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* Integrated Relay outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOptional Analog output support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e18–32V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConsumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypical 8.5 W \/ Max 12.8 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical \u0026amp; Environmental:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDIN Rail (via System 57 rack\/subrack)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e141g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShort circuit and open circuit field protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemote Inhibit and Remote Alarm Set capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e05704-A-0144\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a staple in multi-point gas monitoring systems:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas Refineries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring for combustible gas leaks across four separate locations using a single card slot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing 4-20mA toxic gas transmitters with centralized alarm relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Facilities:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManaging oxygen levels and flammable gas hazards in confined workspaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Plants:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReliable hydrogen monitoring for battery rooms and generator cooling systems.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44089990414435,"sku":"05704-A-0144","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/109.png?v=1774861353","url":"https:\/\/precisemodule.com\/products\/honeywell-05704-a-0144-four-channel-control-card","provider":"Precise Module Ltd.","version":"1.0","type":"link"}