{"product_id":"honeywell-10024-f-f-enhanced-communication-module","title":"Honeywell 10024\/F\/F Enhanced Communication Module","description":"\u003ch1\u003eHoneywell 10024\/F\/F Enhanced Communication Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for dual independent serial communication and protocol conversion in Honeywell Fail Safe Control (FSC) System platforms, the \u003cstrong\u003eHoneywell 10024\/F\/F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3400265\u003c\/strong\u003e Enhanced Communication Module, provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10024\/F\/F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 cm x 8.6 cm x 12.9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial cabinet range (-40 deg C to +70 deg C typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC at 300 mA to 475 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePort Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual independent RS-232 ports (9-pin DB9 female connectors)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU, ASCII, Binary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBaud Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable from 9600 bps to 115.2 kbps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt; 6 kV (galvanically \/ optically isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eOperating within safety instrumented systems, the module incorporates robust optical and galvanic isolation rated in excess of 6 kV across communication interfaces to eliminate ground loops and protect against high-voltage industrial transients. It manages dual independent RS-232 serial channels supporting Modbus RTU, ASCII, and binary protocols at configurable baud rates up to 115.2 kbps. The internal logic maintains deterministic data handling and error checking across cascaded node configurations, ensuring high-integrity telemetry transmission throughout safety-critical networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 10024\/F\/F module support live hot-swapping within the Honeywell FSC rack?\u003c\/p\u003e\n\u003cp\u003eA: No, standard safety instrumented system procedures require de-energizing the respective rack slot or isolating system power before installing or removing communication modules to prevent backplane disruption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cascading capacity for expanding communication ports with this module?\u003c\/p\u003e\n\u003cp\u003eA: The architecture supports cascading up to 16 modules within the system framework to expand serial communication capabilities while maintaining strict protocol synchronization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the module and backplane connector pins for cleanliness and structural integrity prior to insertion into the designated Honeywell FSC system rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the module smoothly along the enclosure guide rails, securing any locking mechanisms to ensure positive electrical contact with the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute RS-232 communication cables away from high-voltage power conduits and ensure proper shield grounding at one end to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67716584833123,"sku":"10024\/F\/F","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/10024-1-1_2.png?v=1790765175","url":"https:\/\/precisemodule.com\/products\/honeywell-10024-f-f-enhanced-communication-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}