{"product_id":"honeywell-10101-1-1-fail-safe-digital-input-module","title":"Honeywell 10101\/1\/1 Fail-Safe Digital Input Module","description":"\u003ch2\u003eHoneywell 10101\/1\/1 Fail-Safe Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10101\/1\/1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e10101\u003c\/strong\u003e Fail-Safe Digital Input Module, operates as a dedicated hardware component for discrete signal acquisition in SIL3-rated safety instrumented systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e10101\/1\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eStandard FSC rack module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e0 deg C to +60 deg C (32 F to 140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e-25 deg C to +85 deg C (-13 F to +185 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003eFail-Safe Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel Count\u003c\/th\u003e\n\u003ctd\u003e16 channels (2 isolated groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic 0 Range\u003c\/th\u003e\n\u003ctd\u003e-3 VDC to +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic 1 Range\u003c\/th\u003e\n\u003ctd\u003e+15 VDC to +30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003ctd\u003e~7.5 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal Consumption\u003c\/th\u003e\n\u003ctd\u003e5 VDC ~50 mA; 24 VDC ~30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExternal Supply\u003c\/th\u003e\n\u003ctd\u003e24 VDC (-15% to +30%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Dissipation\u003c\/th\u003e\n\u003ctd\u003eMax 3.5 W at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003e2.5 kVAC channel-to-system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety Integrity\u003c\/th\u003e\n\u003ctd\u003eSIL3 compliant (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eContinuous self-test routines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 10101\/1\/1 module is designed for IEC 61508 SIL3 applications, ensuring predictable fail-safe execution under fault conditions. Galvanic isolation at 2.5 kVAC separates input channels from internal electronics, preventing fault propagation and maintaining system integrity. Built-in diagnostics continuously verify loop integrity and hardware execution, supporting safety-critical architectures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the typical response time for input signal processing? A: The module processes safety-critical signals in less than 10 ms.\u003c\/p\u003e\n\u003cp\u003eQ: How are the 16 channels organized? A: They are divided into two isolated groups of 8 channels each, providing electrical separation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module require external calibration? A: No. It relies on internal diagnostics and fail-safe logic; external calibration is not applicable.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in designated FSC rack slots with full connector engagement.\u003c\/li\u003e\n\u003cli\u003eEnsure external 24 VDC supply is within tolerance (-15% to +30%).\u003c\/li\u003e\n\u003cli\u003eRoute input wiring separately from high-voltage conductors to minimize interference.\u003c\/li\u003e\n\u003cli\u003eVerify grounding of shielded cables at the rack end only to avoid ground loops.\u003c\/li\u003e\n\u003cli\u003eConfirm diagnostic LED indicators during commissioning to validate channel health.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44567087054947,"sku":"10101\/1\/1","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/10101-2-1_2.png?v=1788852817","url":"https:\/\/precisemodule.com\/products\/honeywell-10101-1-1-fail-safe-digital-input-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}