{"product_id":"honeywell-10315-1-1-redundant-i-o-backplane","title":"Honeywell 10315\/1\/1 Redundant I\/O Backplane","description":"\u003ch2\u003eHoneywell 10315\/1\/1 Redundant I\/O Backplane\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 10315\/1\/1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e10315\u003c\/strong\u003e redundant I\/O backplane, serves as a base board PCB for housing and interconnecting redundant I\/O modules within Honeywell rack-mounted control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e10315\/1\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eU.S.A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e19-inch rack, 3 HE (3U), 84 TE width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 F to 140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChassis Material\u003c\/th\u003e\n\u003ctd\u003eChrome-plated steel (EMI shielding)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e24 VDC integrated busbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent Consumption\u003c\/th\u003e\n\u003ctd\u003ePassive backplane (none)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Current (Faston)\u003c\/th\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax Current (I\/O Pin)\u003c\/th\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIsolation\u003c\/th\u003e\n\u003ctd\u003eChannel-to-channel isolation built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Capacity\u003c\/th\u003e\n\u003ctd\u003e18 slots (positions 1–18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus Drivers\u003c\/th\u003e\n\u003ctd\u003eSlots 20 and 21 for HBD 10100\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eI\/O Connectors\u003c\/th\u003e\n\u003ctd\u003eCN1, CN3, CN5, CN7, CN9, CN11, CN13, CN15, CN17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming Ports\u003c\/th\u003e\n\u003ctd\u003eP1 through P17 (odd numbers only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Bus Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 10315\/1\/1 backplane enforces channel-to-channel isolation across all I\/O slots, preventing electrical interference between modules. Dedicated bus driver slots (20 and 21) maintain deterministic communication across the horizontal bus. EMI shielding via chrome-plated steel chassis ensures stable operation in industrial environments, reducing susceptibility to noise coupling.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O modules can be installed in the 10315\/1\/1 backplane? A: Up to 18 modules can be installed across slots 1–18.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current supported per connector pin? A: Each I\/O connector pin supports up to 2 A, while Faston pins support up to 10 A.\u003c\/p\u003e\n\u003cp\u003eQ: Does the backplane consume power itself? A: No. It is a passive PCB; power is distributed via the integrated busbar.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount securely in a 19-inch rack with 3U clearance.\u003c\/li\u003e\n\u003cli\u003eEnsure grounding continuity between chassis and cabinet earth bus.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring separately from high-voltage conductors to minimize EMI.\u003c\/li\u003e\n\u003cli\u003eVerify bus driver modules are installed in slots 20 and 21 before energizing.\u003c\/li\u003e\n\u003cli\u003eInspect connector seating and shielding integrity prior to commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44567086301283,"sku":"10315\/1\/1","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/10315-1-1_1.png?v=1788852631","url":"https:\/\/precisemodule.com\/products\/honeywell-10315-1-1-redundant-i-o-backplane","provider":"Precise Module Ltd.","version":"1.0","type":"link"}