{"product_id":"honeywell-51120673-101-analog-input-card-module","title":"Honeywell 51120673-101 Analog Input Card Module","description":"\u003ch2\u003eHoneywell 51120673-101 Analog Input Card Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51120673-101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51120673\u003c\/strong\u003e analog input card, operates as a high-level analog input module for direct signal acquisition in Honeywell control system architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003e51120673-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOrigin\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e~300–310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temp\u003c\/th\u003e\n\u003ctd\u003e-20 deg C to +60 deg C (-4 F to +140 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Temp\u003c\/th\u003e\n\u003ctd\u003e-40 deg C to +85 deg C (-40 F to +185 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative Humidity\u003c\/th\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003e≤12 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule Type\u003c\/th\u003e\n\u003ctd\u003eHigh-Level Analog Input Card Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported Signals\u003c\/th\u003e\n\u003ctd\u003e4–20 mA, 0–10 VDC, RTD, Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Supply\u003c\/th\u003e\n\u003ctd\u003e24 VDC (±15%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResponse Time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;10 ms (analog processing time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe 51120673-101 supports integration with Honeywell analog subsystems using 4-20 mA HART loop protocols. Signal conditioning includes cold junction compensation (CJC) for thermocouple inputs, ensuring accurate temperature measurement across varying ambient conditions. Channel-to-channel isolation maintains measurement integrity in multi-signal environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the typical response time of the module? A: The analog processing time is less than 10 ms.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support thermocouple inputs directly? A: Yes. Thermocouple inputs are supported with cold junction compensation for accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What is the nominal supply voltage? A: The module operates at 24 VDC nominal with ±15% tolerance.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in designated Honeywell chassis slots with full connector engagement.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for analog signals, grounding shields at the rack end only.\u003c\/li\u003e\n\u003cli\u003eSeparate analog wiring from high-voltage conductors to minimize interference.\u003c\/li\u003e\n\u003cli\u003eVerify polarity of the 24 VDC supply before energizing.\u003c\/li\u003e\n\u003cli\u003eMaintain ambient conditions within specified operating temperature and humidity limits.\u003c\/li\u003e\n\u003cli\u003eConfirm calibration for RTD and thermocouple inputs during commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44571472134243,"sku":"51120673-101","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/51305508-100_3.png?v=1788779966","url":"https:\/\/precisemodule.com\/products\/honeywell-51120673-101-analog-input-card-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}