{"product_id":"honeywell-51202306-005-ac-input-filter-module-emi-rfi-suppression-for-tdc-3000-experion-systems","title":"Honeywell 51202306-005 AC Input Filter Module | EMI\/RFI Suppression for TDC 3000 \/ Experion Systems","description":"\u003ch3\u003eShopify Product Title:\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eHoneywell 51202306-005 AC Input Filter Module | EMI\/RFI Noise Suppression for TDC 3000 \u0026amp; Experion HPM\/ APM\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProduct Description:\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell 51202306-005\u003c\/span\u003e is a highly effective \u003cspan\u003eAC Input Filter Module\u003c\/span\u003e designed to ensure stable and clean power supply to \u003cspan\u003eHoneywell TDC 3000\u003c\/span\u003e and \u003cspan\u003eExperion PKS (Process Knowledge System)\u003c\/span\u003e controllers. Positioned as the first line of defense in the power distribution system, this module mitigates electromagnetic interference (EMI) and radio frequency interference (RFI), providing critical protection for sensitive electronics inside \u003cspan\u003eI\/O modules\u003c\/span\u003e and \u003cspan\u003eprocessors\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eThis filter module is commonly installed in the \u003cspan\u003eHPM (High-Performance Process Manager)\u003c\/span\u003e and \u003cspan\u003eAPM (Advanced Process Manager)\u003c\/span\u003e cabinets, where it serves to prevent harmful power surges or electrical noise from compromising the performance and reliability of the control system. By ensuring that the power entering the system is clean and stable, it helps avoid potential \u003cspan\u003esystem resets\u003c\/span\u003e, \u003cspan\u003edata corruption\u003c\/span\u003e, or component failures.\u003c\/p\u003e\n\u003ch4\u003eKey Features \u0026amp; Functions:\u003c\/h4\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEMI and RFI Filtering\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe \u003cspan\u003e51202306-005\u003c\/span\u003e uses an advanced combination of inductors and capacitors to suppress high-frequency noise from \u003cspan\u003eindustrial machinery\u003c\/span\u003e, \u003cspan\u003emotors\u003c\/span\u003e, and \u003cspan\u003evariable frequency drives (VFDs)\u003c\/span\u003e that often share the same power grid as the control system. This prevents electrical noise from disrupting control signals and system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTransient Voltage Suppression\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEquipped with \u003cspan\u003eMetal Oxide Varistors (MOVs)\u003c\/span\u003e, this module protects downstream components from voltage spikes caused by external sources like \u003cspan\u003elightning strikes\u003c\/span\u003e or switching transients, ensuring the protection of costly power supply units (e.g., \u003cspan\u003e51304362-100\u003c\/span\u003e or \u003cspan\u003e51304362-150\u003c\/span\u003e).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndustrial-Grade Durability\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt for continuous operation in harsh environments, the \u003cspan\u003e51202306-005\u003c\/span\u003e is designed to withstand high temperatures, vibrations, and the demanding conditions found in industries like \u003cspan\u003eoil refineries\u003c\/span\u003e, \u003cspan\u003echemical plants\u003c\/span\u003e, and \u003cspan\u003epulp and paper mills\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePassive Component Reliability\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAs a \u003cspan\u003epassive filtration device\u003c\/span\u003e, it boasts an \u003cspan\u003eextremely high Mean Time Between Failures (MTBF)\u003c\/span\u003e. In case of a \u003cspan\u003ecatastrophic power surge\u003c\/span\u003e, the filter sacrifices itself (via internal fusing or MOV failure), thereby protecting more critical and expensive system components like controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem Integration\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThis module is specifically engineered to work seamlessly within Honeywell’s system architecture, filtering incoming \u003cspan\u003e120 VAC\u003c\/span\u003e or \u003cspan\u003e240 VAC\u003c\/span\u003e power. Once filtered, the clean power is delivered to the \u003cspan\u003epower supply modules\u003c\/span\u003e (e.g., \u003cspan\u003e51309288-225\u003c\/span\u003e), which then convert it to DC power for the controller backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ol\u003e\n\u003ch4\u003eTechnical Specifications:\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e51202306-005\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion HPM \/ APM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC or 240 VAC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 20A (System dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eEMI\/RFI Filtering \u0026amp; Transient Suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCabinet Rack Mount \/ Power Entry Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +70°C (32°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.2 kg (2.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eInstallation Considerations:\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMounting Surface\u003c\/span\u003e: Ensure that the surface is \u003cspan\u003eflat\u003c\/span\u003e and \u003cspan\u003esmooth\u003c\/span\u003e (milled or spot-faced) to optimize the power flow and achieve the best noise suppression performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTorque Specifications\u003c\/span\u003e: When installing the module, it is recommended to torque the mounting hardware to \u003cspan\u003e4.5 N·m (40 in-lb)\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCabling\u003c\/span\u003e: Use \u003cspan\u003eshielded cables\u003c\/span\u003e for connecting the filter module to the power entry panel to minimize electromagnetic interference (EMI) during operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eTechnical Note\u003c\/span\u003e: The \u003cspan\u003e51202306-005\u003c\/span\u003e requires proper integration with Honeywell’s \u003cspan\u003ePower Supply Units\u003c\/span\u003e and \u003cspan\u003econtrollers\u003c\/span\u003e. Ensure the system is configured to deliver appropriate filtered power to the I\/O modules for optimal performance.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44089969836131,"sku":"51202306-005","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/51202306-005.jpg?v=1774858605","url":"https:\/\/precisemodule.com\/products\/honeywell-51202306-005-ac-input-filter-module-emi-rfi-suppression-for-tdc-3000-experion-systems","provider":"Precise Module Ltd.","version":"1.0","type":"link"}