{"product_id":"honeywell-51303932-476-si-fta-modbus-ce-cc-1-ch","title":"HONEYWELL 51303932-476 SI FTA Modbus CE CC (1 ch)","description":"\u003ch3 class=\"\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e51303932-476 (MC-TSIM12)\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability Serial Device Interface (SI) Field Termination Assembly designed for the Honeywell TDC 3000 and Experion PKS control systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific module facilitates asynchronous serial communication between the DCS and third-party devices,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esuch as programmable logic controllers (PLCs),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emotor control centers,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eor analytical instruments that utilize the Modbus RTU protocol.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eEngineered for longevity in challenging industrial climates,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e51303932-476\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis both CE Compliant and Conformal Coated.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe conformal coating provides a specialized polymeric film that shields the printed circuit board from moisture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethermal shock,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand corrosive contaminants.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis single-channel FTA supports both EIA-232 and EIA-485\/422 physical interfaces,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewith the specific communication parameters pre-configured in the factory-programmed plug-in firmware module.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eMC-TSIM12\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePart Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003e51303932-476\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModbus RTU (Asynchronous Serial)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterface Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelectable EIA-232 (RS-232) or EIA-422\/485 (RS-422\/RS-485)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle (1) Channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-redundant configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Connectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e* Primary Interface: DB-25 type connector (J2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField Wiring: Compression-type terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCE Compliant (Meets EU health, safety, and environmental standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal Coated (CC) for moisture and chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEIA-232 Cable Limit:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaximum 15 meters (50 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eForm Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSize A — 6 inches (152 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFirmware:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFactory-preprogrammed plug-in module tailored to the associated IOP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eStandard FTA mounting base compatible\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51303932-476\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for integrating non-Honeywell hardware into the Ovation or Experion environment, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Metering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCollecting real-time electrical data from Modbus-enabled power monitors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVariable Frequency Drives (VFDs):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControlling motor speeds and monitoring drive diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Computers:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eImporting high-accuracy custody transfer data into the DCS database.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy PLC Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBridging data from standalone Modbus serial controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44089002950755,"sku":"51303932-476","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/87.png?v=1774849976","url":"https:\/\/precisemodule.com\/products\/honeywell-51303932-476-si-fta-modbus-ce-cc-1-ch","provider":"Precise Module Ltd.","version":"1.0","type":"link"}