{"product_id":"honeywell-51304584-100-epdgp-i-o-board","title":"Honeywell 51304584-100 EPDGP I\/O Board","description":"\u003ch1\u003eHoneywell 51304584-100 EPDGP I\/O Board\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003eHoneywell 51304584-100\u003c\/strong\u003e is an EPDGP I\/O board designed for Honeywell TDC 3000 Universal Station environments. The board functions as a peripheral interface module that manages communication between the operator station and connected external devices. As an updated EPDG\/EPDG2 interface solution, it provides centralized connectivity for display, input, printing, and storage peripherals within the TDC 3000 architecture.\u003c\/p\u003e\n\u003ch3\u003eUniversal Station Peripheral Interface\u003c\/h3\u003e\n\u003cp\u003eThe 51304584-100 is intended for use within the \u003cstrong\u003eHoneywell TDC 3000\u003c\/strong\u003e Distributed Control System and is associated with the \u003cstrong\u003eUniversal Station\u003c\/strong\u003e platform.\u003c\/p\u003e\n\u003cp\u003eIts primary role is to provide communication and interface services between the operator workstation and connected peripheral equipment. The board acts as an intermediary layer that allows external devices to exchange information with the operator station environment.\u003c\/p\u003e\n\u003ch3\u003eSupported Peripheral Devices\u003c\/h3\u003e\n\u003cp\u003eThe EPDGP I\/O Board supports multiple operator-station peripherals through integrated interface connections.\u003c\/p\u003e\n\u003cp\u003eSupported devices include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVideo displays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCursor control devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTrackballs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMice\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperator keyboards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrinters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZip drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBernoulli storage drives\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis peripheral integration capability enables the Universal Station to support operator interaction, display functions, reporting, and removable media operations.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe board is described as a newer-generation interface card derived from the EPDG and EPDG2 peripheral interface architecture.\u003c\/p\u003e\n\u003cp\u003eIts design supports installation within Honeywell TDC system hardware while providing the connectivity functions required by operator workstation peripherals.\u003c\/p\u003e\n\u003ch3\u003eCommunication and Processing Resources\u003c\/h3\u003e\n\u003cp\u003eAccording to the supplied information, the board includes processing and memory resources to support peripheral communication functions.\u003c\/p\u003e\n\u003cp\u003eAvailable hardware resources include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e128 MHz ARM Cortex-A8 processor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e64 MB Flash memory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e32 MB SDRAM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese resources support data handling and interface management between the Universal Station and connected devices.\u003c\/p\u003e\n\u003ch3\u003eCommunication Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe board is reported to support several communication interface standards depending on the overall system topology.\u003c\/p\u003e\n\u003cp\u003eAvailable interfaces include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRS-485\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCAN\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eActual interface utilization depends on the installed system configuration and associated control platform requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304584-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEPDGP I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eUniversal Station Peripheral Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Station Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e128 MHz ARM Cortex-A8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e64 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDRAM\u003c\/td\u003e\n\u003ctd\u003e32 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eRS-485, CAN, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC to 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Integration Considerations\u003c\/h3\u003e\n\u003cp\u003eThe 51304584-100 is intended for operator-station peripheral communication rather than process I\/O acquisition. When replacing an existing board, the installed Universal Station configuration and connected peripheral devices should be verified to ensure compatibility.\u003c\/p\u003e\n\u003cp\u003eBecause the board serves as an interface component within the TDC 3000 workstation environment, peripheral connectivity requirements should be assessed before installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the 51304584-100 EPDGP I\/O Board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The board provides peripheral interface functionality for Honeywell TDC 3000 Universal Stations, enabling communication between the operator station and connected external devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which peripherals can be connected through this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied information identifies support for video displays, keyboards, cursor-control devices, printers, and removable storage devices such as Zip and Bernoulli drives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 51304584-100 a process I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The board is described as a Universal Station peripheral interface card intended for workstation and operator-interface communications rather than direct field signal acquisition.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67752633270371,"sku":"51304584-100","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/51304584-100_2_b323722d-8ac5-4a3a-9b17-34c40b8ddcf7.png?v=1791863721","url":"https:\/\/precisemodule.com\/products\/honeywell-51304584-100-epdgp-i-o-board","provider":"Precise Module Ltd.","version":"1.0","type":"link"}