{"product_id":"honeywell-620-0036-ac-power-supply-module","title":"Honeywell 620-0036 AC Power Supply Module","description":"\u003ch1\u003eHoneywell 620-0036 AC Power Supply Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for regulated power conversion and distribution in programmable logic controller platforms, the \u003cstrong\u003eHoneywell 620-0036\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e620-0036\u003c\/strong\u003e AC Power Supply Module, provides direct physical and electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e620-0036\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.78 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.8 cm x 7.6 cm x 27.9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial cabinet range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115\/230 VAC, 2.0\/1.0 A, 47 to 63 Hz input\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e115 VAC and 230 VAC selectable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRegulated power delivery for PLC processors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard rack or chassis mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eWhile functioning primarily as a robust alternating current power conversion unit, the module ensures isolated power distribution to safeguard sensitive processor backplanes against line transients and voltage fluctuations. The circuitry accommodates dual input ranges of 115 VAC and 230 VAC at 47 to 63 Hz while maintaining steady low-voltage DC output rails for system logic. Built-in thermal management and filtering minimize electromagnetic interference across cabinet power busses, preserving signal integrity throughout the connected industrial control network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the input voltage selection be adjusted manually on the 620-0036 module?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports selectable input ranges for 115 VAC and 230 VAC via internal jumpers or terminal configuration to match local plant supply requirements prior to energization.\u003c\/p\u003e\n\u003cp\u003eQ: Does the power supply module support hot-swap capabilities within the PLC rack?\u003c\/p\u003e\n\u003cp\u003eA: No, standard system safety guidelines require completely isolating and powering down the rack enclosure before inserting or removing the power supply unit to prevent electrical shock or backplane damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the module securely into the designated chassis slot of the Honeywell PLC system, ensuring all mechanical retention fasteners are fully tightened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the input voltage jumper or switch configuration matches the incoming AC line supply (115 VAC or 230 VAC) before connecting mains power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute AC input wiring and DC output distribution cables away from high-voltage motor leads and use proper chassis grounding to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67716310663267,"sku":"620-0036","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/620-0036_3.png?v=1792049807","url":"https:\/\/precisemodule.com\/products\/honeywell-620-0036-ac-power-supply-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}