{"product_id":"honeywell-80360206-001-circuit-board","title":"Honeywell 80360206-001 Circuit Board","description":"\u003ch1\u003eHoneywell 80360206-001 Circuit Board\u003c\/h1\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 80360206-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e80360206-001\u003c\/strong\u003e Circuit Board, operates as a dedicated hardware component for communication interface processing within Honeywell TDC 2000 and TDC 3000 system architectures. The board provides a communication bridge between the rack backplane bus and external processing interfaces, supporting host gateway data exchange and multinode communication functions.\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eHardware Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e80360206-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunications Line Interface Circuit Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Category\u003c\/td\u003e\n\u003ctd\u003eComputer Gateway \/ Communication Interface Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Platforms\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 2000, TDC 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eBackplane-to-External Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHost Gateway and Multinode Communications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSlot-In Paddleboard Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical or Horizontal Chassis Integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.9 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCommunication Gateway and Backplane Interface Functions\u003c\/h3\u003e\n\u003cp\u003eThe 80360206-001 functions as a communication interface board within Honeywell distributed control system environments. The board manages data transfer between rack-resident control hardware and external communication pathways required for host-level system interaction.\u003c\/p\u003e\n\u003cp\u003eWithin multinode architectures, the module operates alongside complementary communication interface hardware to support data movement across system segments. The board exchanges information through the chassis backplane while maintaining communication links required by gateway and supervisory processing functions.\u003c\/p\u003e\n\u003cp\u003eIts slot-in paddleboard construction allows installation within multi-node communication chassis where centralized communication management and backplane access are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the 80360206-001 board?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The board functions as a communication gateway interface between the rack backplane bus and external processing or communication links.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Honeywell platforms commonly utilize this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module is associated with Honeywell TDC 2000 and TDC 3000 system architectures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 80360206-001 an I\/O module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The available documentation identifies the board as a communications line interface and gateway-related circuit board rather than a field I\/O acquisition module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify slot assignment before insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully seat the board into the chassis backplane connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect edge connectors for contamination or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemove and install the board with system power isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm communication status following startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67715407970403,"sku":"80360206-001","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/51401996-100_2.png?v=1789713270","url":"https:\/\/precisemodule.com\/products\/honeywell-80360206-001-circuit-board","provider":"Precise Module Ltd.","version":"1.0","type":"link"}