{"product_id":"honeywell-8c-taoxa1-analog-output-iota-module","title":"Honeywell 8C- TAOXA1 Analog Output IOTA Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (8C-TAOXA1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Input Output Termination Assembly (IOTA) designed for the Honeywell Series 8 platform. This module provides the physical interface and termination points for 16-channel analog output signals, supporting both standard and HART-enabled modules. To ensure longevity in harsh industrial climates, this unit features a conformal coating that protects sensitive circuitry against moisture, dust, and corrosive elements. Its compact 6-inch footprint is optimized for high-density cabinet installations where rail space is at a premium.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComponent Type\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output Termination Assembly (IOTA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-Redundant (Simplex)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell Series 8 Controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(HART),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAONA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Non-HART)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Operating Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e110 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConversion Resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e16 bits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4-20 mA (via 250 Ω resistance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Scan Frequency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e50 ms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Precision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±0.075% of full-scale (at 23.5°C ± 2°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection (CMRR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e70 dB (DC to 60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection (NMRR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19 dB (at 60 Hz)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFilter Characteristics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-pole RC, -3 dB @ 6.5 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Voltage Tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e±30 Volts peak (non-destructive)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e6 inches (152 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal Coated (CC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Application\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-TAOXA1 (8C-TAOXA1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the bridge between the Series 8 control processor and field elements such as control valves, positioners, and variable speed drives.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for mounting on standard Series 8 carrier rows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for non-critical loops where redundancy is not a requirement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in support for HART digital pass-through when paired with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8C-PAOHA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44093440098403,"sku":"8C- TAOXA1","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/611f6342312e1d3fda00d17e9639f0cf_c5b84343-aa41-4616-9529-a3f112df11f7.jpg?v=1714129565","url":"https:\/\/precisemodule.com\/products\/honeywell-8c-taoxa1-analog-output-iota-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}