{"product_id":"honeywell-8c-tcnt01-51307032-175-input-output-termination-assembly","title":"Honeywell 8C-TCNT01 51307032-175 Input\/Output Termination Assembly","description":"\u003ch1\u003eHoneywell 8C-TCNT01 51307032-175 Input\/Output Termination Assembly\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 8C-TCNT01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e51307032-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInput\/Output Termination Assembly) operates as a dedicated field termination platform for Honeywell C300 controller systems. It provides physical connection points for controller communications, power distribution, redundancy interfaces, and field cabling within Honeywell Experion and TPS control architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TCNT01 \/ 51307032-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInput\/Output Termination Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eC300 Controller Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eField cable termination and signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Rating\u003c\/td\u003e\n\u003ctd\u003e0.31 A @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eFTE, IO Link, Redundancy, Battery, Time Source Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eControl cabinet mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eController Interface Architecture\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TCNT01 serves as the termination layer for Honeywell C300 controller installations. The assembly provides dedicated connection points for controller communication networks, redundant system links, power input distribution, battery connections, and synchronization interfaces used by the control platform.\u003c\/p\u003e\n\u003ch3\u003eCommunication and Signal Routing\u003c\/h3\u003e\n\u003cp\u003eWithin a DCS environment, the IOTA establishes the physical interface between the controller and external system wiring. The assembly supports orderly cable management while maintaining communication pathways for Fault Tolerant Ethernet (FTE), IO Link communications, and controller redundancy functions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 8C-TCNT01 a processor module?\u003c\/strong\u003e\u003cbr\u003eA: No. It is an Input\/Output Termination Assembly used to connect and distribute field and system wiring for the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply is required?\u003c\/strong\u003e\u003cbr\u003eA: The assembly is designed for 24 VDC controller power distribution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the assembly support controller redundancy connections?\u003c\/strong\u003e\u003cbr\u003eA: Yes. Dedicated redundancy connection points are included as part of the IOTA design.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify compatibility with the designated Honeywell C300 controller assembly before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all field and communication wiring is terminated according to the assigned terminal designations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate communication cables from high-energy power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm grounding continuity before system energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect all terminal connections and connector seating during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46216309276771,"sku":"8C-TCNT01 51307032-175","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/8C-TAOX61.png?v=1788422275","url":"https:\/\/precisemodule.com\/products\/honeywell-8c-tcnt01-51307032-175-input-output-termination-assembly","provider":"Precise Module Ltd.","version":"1.0","type":"link"}