{"product_id":"honeywell-900b01-0001-analog-output-module","title":"Honeywell 900B01-0001 Analog Output Module","description":"\u003ch1\u003eHoneywell 900B01-0001 Analog Output Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for analog signal output generation in Honeywell control systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell 900B01-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e900B01-0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output Module) provides direct electrical output through four isolated analog channels. The module converts controller data into field-level current signals for interfacing with final control elements, recorders, and process instrumentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900B01-0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0 mA to 21.8 mA, configurable to 4 mA to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eD\/A Resolution\u003c\/td\u003e\n\u003ctd\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Resistance\u003c\/td\u003e\n\u003ctd\u003e750 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003eSynchronous with controller scan cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eMinimum current sensing, built-in fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC Loading\u003c\/td\u003e\n\u003ctd\u003e40 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC Loading\u003c\/td\u003e\n\u003ctd\u003e200 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-to-Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e600 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137 mm x 35.6 mm x 66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.408 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eG3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC 40 mA max, 24 VDC 200 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Analog Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe 900B01-0001 incorporates four electrically isolated analog output channels designed to reduce interaction between independently controlled output loops. Channel-to-channel isolation is rated at 500 VDC, while field-to-logic isolation is rated at 600 VDC.\u003c\/p\u003e\n\u003cp\u003eThe module supports configurable current output operation, including standard 4 mA to 20 mA process control loops. Galvanic isolation assists in reducing the effects of ground potential differences and field wiring disturbances between output circuits and controller electronics.\u003c\/p\u003e\n\u003cp\u003eBuilt-in output diagnostics continuously monitor channel operation and provide fault detection capability. Minimum current sensing functions support verification of output loop integrity during operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support standard 4 mA to 20 mA control loops?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The output range is user-configurable and supports standard 4 mA to 20 mA analog current applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum field load supported by each output channel?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach output channel supports load resistance up to 750 Ohm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are the output channels electrically isolated from one another?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. The module provides 500 VDC channel-to-channel galvanic isolation and 600 VDC field-to-logic isolation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify controller and backplane compatibility before installing the module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDe-energize the I\/O chassis before inserting or removing the module unless site procedures specifically permit online maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute analog output wiring separately from AC power and motor circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded instrumentation cable for low-noise analog signal transmission where required by site standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields according to plant grounding practices to avoid ground loop conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm field load resistance does not exceed the specified 750 Ohm limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify output scaling and loop calibration after installation and before placing the control loop into service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67670490775651,"sku":"900B01-0001","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/900H02-0001_2.jpg?v=1790666793","url":"https:\/\/precisemodule.com\/products\/honeywell-900b01-0001-analog-output-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}