{"product_id":"honeywell-9202-ets-mm-sc-industrial-security-appliance","title":"Honeywell 9202-ETS-MM-SC Industrial Security Appliance","description":"\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e9202-ETS-MM-SC\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance industrial security appliance specifically designed for SCADA and process control networks that utilize fiber optic backbones. Unlike standard copper-based firewalls, this model features dual\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e100BASE-FX multimode fiber\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003einterfaces, allowing for secure, EMI-resistant communication over distances up to 5,000 meters.\u003c\/p\u003e\n\u003cp\u003eOperating as a transparent Layer 2 bridge, the\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e9202-ETS-MM-SC\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eprovides \"plug-and-protect\" security. It can be installed into existing fiber links without requiring IP address changes or network re-engineering. This makes it an essential tool for isolating critical control zones (such as turbine controllers or PLC clusters) from broader plant networks, effectively mitigating the risk of malware propagation and unauthorized access.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet Interfaces\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNet 1\u003c\/span\u003e: 100BASE-FX, Multimode Fiber (SC Connectors).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNet 2\u003c\/span\u003e: 100BASE-FX, Multimode Fiber (SC Connectors).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFiber Performance\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMultimode (MM)\u003c\/span\u003e: Supports 50\/125 μm cabling up to 5,000 meters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSinglemode (SM) Support\u003c\/span\u003e: Extendable up to 30 kilometers with appropriate modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePeripheral Interfaces\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e: 1 x USB port for local setup and security profile loading.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDigital Input\u003c\/span\u003e: 1 x 2-pin plug-in terminal block for external status triggering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSignaling Contact\u003c\/span\u003e: Integrated relay (Max 60V DC \/ 30V AC SELV, 1A) for alarm output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower Architecture\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e: 12–48V DC or 24V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e: Dual power inputs for high-availability installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConsumption\u003c\/span\u003e: Ultra-low 5 Watts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecurity \u0026amp; Software\u003c\/span\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManagement\u003c\/span\u003e: Controlled via\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eMTL Tofino Configurator (TC)\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003esoftware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStandard Modules\u003c\/span\u003e: Firewall, Event Logger, and NetConnect.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDeep Packet Inspection (DPI)\u003c\/span\u003e: Supports optional enforcer modules for Modbus TCP, OPC, EtherNet\/IP, DNP3, IEC104, and GOOSE.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eManufacturing Origin\u003c\/span\u003e: USA \/ Global.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplication and Cyber Defense\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003e9202-ETS-MM-SC\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis ideally suited for large-scale industrial sites like refineries, offshore platforms, and power plants where long-distance fiber runs are standard. By enforcing protocol-specific rules (DPI), the appliance doesn't just block IP addresses; it inspects the actual commands being sent to the hardware. For example, it can be configured to allow a workstation to \"Read\" data from a PLC via Modbus while blocking any \"Write\" or \"Programming\" commands, ensuring that only authorized operational changes can occur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44092532588643,"sku":"9202-ETS-MM-SC","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/159.png?v=1774941633","url":"https:\/\/precisemodule.com\/products\/honeywell-9202-ets-mm-sc-industrial-security-appliance","provider":"Precise Module Ltd.","version":"1.0","type":"link"}