{"product_id":"honeywell-cc-pdis01-digital-input-soe-module-experion-pks","title":"Honeywell CC-PDIS01 Digital Input SOE Module Experion PKS","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PDIS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDigital Input Sequence of Events (DISOE) module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for integration with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExperion PKS Series C I\/O system\u003c\/strong\u003e. It provides fast, time-stamped capture of 24V DC discrete signals from field devices, enabling accurate post-event diagnostics in critical industrial applications.\u003c\/p\u003e\n\u003cp\u003eThis module is ideal for environments where millisecond-level event sequencing is essential, including power generation, chemical processing, and oil and gas emergency shutdown systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PDIS01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterfaces directly with 24V DC discrete field signals and communicates with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC300 controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia an I\/O Termination Assembly (IOTA). Its main function is to capture the precise timing of digital events, providing critical Sequence of Events (SOE) data for control, monitoring, and safety analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Functionalities:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-resolution SOE recording:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMillisecond-accurate timestamps for event sequencing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant-ready design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports optional redundancy with compatible IOTA modules (CC-TDIL11).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-board excitation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupplies 24V DC to field contacts directly, reducing cabling complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic features:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDetects open or broken wires to maintain data integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eCC-PDIS01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDigital Input Sequence of Events (DISOE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e32 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e18–30 VDC (Nominal 24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eON Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e≥ 13 VDC or ≥ 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOFF Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e≤ 5 VDC or ≤ 1.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e4.2 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSOE Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eScan Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eNormal 20 ms, Fast 5 ms, SOE 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGalvanic isolation up to 1500 VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePanel or rack-mount via IOTA assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine trips and breaker monitoring in power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency shutdown systems in oil and gas facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterlock and safety system monitoring in chemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed event logging in critical process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many digital inputs does the CC-PDIS01 support?\u003c\/strong\u003e\u003cbr\u003eA: It supports 32 discrete input channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the time resolution for event capture?\u003c\/strong\u003e\u003cbr\u003eA: Events are captured with 1 millisecond accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module provide power to field devices?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it can supply 24V DC directly to connected field contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is redundancy supported?\u003c\/strong\u003e\u003cbr\u003eA: Optional redundancy is available when paired with a compatible IOTA module such as CC-TDIL11.\u003c\/p\u003e\n\u003cp style=\"box-sizing: inherit; color: rgba(18, 18, 18, 0.75); font-family: Assistant, sans-serif; font-size: 19.2px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: 0.72px; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44120801804387,"sku":"CC-PDIS01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/HONEYWELLCC-PDIS01-3.jpg?v=1776308902","url":"https:\/\/precisemodule.com\/products\/honeywell-cc-pdis01-digital-input-soe-module-experion-pks","provider":"Precise Module Ltd.","version":"1.0","type":"link"}