{"product_id":"honeywell-cc-pdod51-32-channel-digital-output-module-series-c","title":"Honeywell CC-PDOD51 32-Channel Digital Output Module Series C","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 32-channel 24 VDC digital output module designed for the Experion PKS Series C platform. Utilizing a sink (open-drain) output configuration, it enables precise control of field devices while offering robust protection against electrical faults and harsh environmental conditions. Its vertical wedge form factor allows efficient mounting on Input\/Output Termination Assemblies (IOTA), supporting both non-redundant and fully redundant configurations.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density 32-channel digital output module in a compact design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSink (open-drain) outputs for controlling solenoids, relays, and indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFully conformal-coated for corrosion and contaminant resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports safe-state configurations (FAILOPT) with hold-last-value or shed-to-safe options\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in overcurrent protection for each channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem-to-field galvanic isolation rated at 1000 VAC RMS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth align=\"left\"\u003eFeature\u003c\/th\u003e\n\u003cth align=\"left\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eDigital Output, Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOutput Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eSink (Open Drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMaximum Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eMaximum Load Current per Channel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.1 A (100 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSwitching Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e≤ 10 ms (ON\/OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOff-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e24 VDC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0 VDC @ 0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOff-State Leakage Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e100 μA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e1000 VAC RMS, system-to-field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eIOTA Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eCC-TDOD51 (Non-Redundant), CC-TDOD61 (Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eExperion PKS R410 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is widely used in industrial process control, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSolenoid valve actuation for fluids and gases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfacing with relays for higher-power AC\/DC loads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus indication with LEDs or pilot lights\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAudible alarms for process warnings or safety signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module be used in redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when installed on a CC-TDOD61 IOTA, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCC-PDOD51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports fully redundant operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of devices can be driven by this module?\u003c\/strong\u003e\u003cbr\u003eA: The sink outputs are ideal for 24 VDC solenoids, relays, and LED indicators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module handle faults?\u003c\/strong\u003e\u003cbr\u003eA: Each channel has electronic overcurrent protection, and outputs can be configured to fail safely on loss of communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are there similar modules in Series C?\u003c\/strong\u003e\u003cbr\u003eA: The CC-PDOD51 focuses on high-density digital outputs; alternatives like the CC-PDOD41 provide fewer channels but similar protection features.\u003c\/p\u003e\n\u003cp style=\"box-sizing: inherit; color: rgba(18, 18, 18, 0.75); font-family: Assistant, sans-serif; font-size: 19.2px; font-style: normal; font-variant-ligatures: normal; font-variant-caps: normal; font-weight: 400; letter-spacing: 0.72px; orphans: 2; text-align: start; text-indent: 0px; text-transform: none; widows: 2; word-spacing: 0px; -webkit-text-stroke-width: 0px; white-space: normal; background-color: rgb(255, 255, 255); text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44144199860323,"sku":"CC-PDOD51","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/HONEYWELLCC-PDOD51-2.jpg?v=1777282790","url":"https:\/\/precisemodule.com\/products\/honeywell-cc-pdod51-32-channel-digital-output-module-series-c","provider":"Precise Module Ltd.","version":"1.0","type":"link"}