{"product_id":"honeywell-cc-taox11-51308353-175-input-output-termination-assembly","title":"Honeywell CC-TAOX11 51308353-175 Input\/Output Termination Assembly","description":"\u003ch1\u003eHoneywell CC-TAOX11 51308353-175 Input\/Output Termination Assembly\u003c\/h1\u003e\n\u003cp\u003eConfigured for analog output signal termination and field wiring management in Honeywell Series C architectures, the \u003cstrong\u003eHoneywell CC-TAOX11 51308353-175\u003c\/strong\u003e (\u003cstrong\u003eCC-TAOX11\u003c\/strong\u003e Input\/Output Termination Assembly) provides direct physical and electrical execution between field devices and associated analog output modules. The assembly supports redundant module installation, field signal distribution, hot-swappable maintenance procedures, and termination of up to sixteen analog output channels within Series C control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TAOX11 51308353-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eInput\/Output Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Platform\u003c\/td\u003e\n\u003ctd\u003eSeries C IOTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eCC-PAOH01 Analog Output Module and non-HART analog output modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e16 output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003e1:1 redundant module support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, adjustable 0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC via Series C I\/O Link backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Resistance\u003c\/td\u003e\n\u003ctd\u003e800 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.3 % full scale at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReadback Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-4 % full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05 % full scale nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05 % full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003eLess than 100 mV peak-to-peak at power-line frequency with 250 Ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eWithin 80 ms to 1 % of final value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Open Circuit Voltage\u003c\/td\u003e\n\u003ctd\u003e22 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.005 % full scale per deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e12 in (approximately 304.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eG3 coating per ISA corrosion environment requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Terminals\u003c\/td\u003e\n\u003ctd\u003eRemovable terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap Support\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eWhen paired with the CC-PAOH01 analog output module, the CC-TAOX11 functions as the field termination platform for 4-20 mA analog output circuits, including HART-enabled applications. The assembly routes output signals from the associated I\/O electronics to field instrumentation through removable terminal assemblies while preserving service accessibility.\u003c\/p\u003e\n\u003cp\u003eThe termination architecture supports output loop loading up to 800 Ohm under the specified supply conditions. Channel wiring remains accessible without requiring removal of field conductors during module replacement procedures, reducing maintenance intervention on commissioned field loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CC-TAOX11 support redundant analog output modules?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The assembly provides 1:1 redundancy capability and incorporates dual module positions to support redundant output module installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can field wiring remain connected during module replacement?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The removable terminal arrangement and hot-swappable design allow module servicing without disconnecting existing field wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are diagnostic functions available for connected output channels?\u003c\/strong\u003e\u003cbr\u003eA: When used with the compatible output module, the assembly supports open-wire detection and short-circuit alarm reporting functions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the termination assembly in the designated Series C cabinet location and verify secure mechanical engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm compatibility between the installed IOTA and the selected analog output module before energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between analog output wiring and high-energy power circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded instrumentation cable for low-level analog signal routing where required by plant standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate cable shields according to the site's grounding practice and avoid unintended ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify polarity of every output loop before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm redundancy configuration and module seating when deploying dual-module installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eValidate open-wire and fault diagnostic indications during startup testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecord terminal assignments before maintenance activities to preserve channel traceability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":67729836212323,"sku":"CC-TAOX11 51308353-175","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/DC-TAIL51_2.png?v=1789973340","url":"https:\/\/precisemodule.com\/products\/honeywell-cc-taox11-51308353-175-input-output-termination-assembly","provider":"Precise Module Ltd.","version":"1.0","type":"link"}