{"product_id":"honeywell-cc-tpix11-8-channel-high-speed-pulse-input-module-for-exhoneywell-cc-tpix11-8-channel-high-speed-pulse-input-module-for-experion®-pks-c300perion®-pks-c300","title":"Honeywell CC-TPIX11 | 8-Channel High-Speed Pulse Input Module for ExHoneywell CC-TPIX11 | 8-Channel High-Speed Pulse Input Module for Experion® PKS C300perion® PKS C300","description":"\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Description:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eHoneywell CC-TPIX11\u003c\/span\u003e is a high-performance \u003cspan\u003ePulse Input Module\u003c\/span\u003e designed for the \u003cspan\u003eExperion® PKS (Process Knowledge System)\u003c\/span\u003e, specifically within the \u003cspan\u003eC300\u003c\/span\u003e controller family. Part of the \u003cspan\u003eSeries C I\/O platform\u003c\/span\u003e, this module is engineered for interfacing with high-speed pulse-generating field devices, such as \u003cspan\u003eflow meters\u003c\/span\u003e, \u003cspan\u003espeed sensors\u003c\/span\u003e, and \u003cspan\u003etachometers\u003c\/span\u003e. It offers the precision and speed required for demanding industrial applications, such as \u003cspan\u003ecustody transfer\u003c\/span\u003e and \u003cspan\u003emonitoring high-speed rotating equipment\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike typical digital input modules, the \u003cspan\u003eCC-TPIX11\u003c\/span\u003e supports pulse frequencies up to \u003cspan\u003e100 kHz\u003c\/span\u003e, making it ideal for applications where real-time pulse counting or frequency measurement is critical. This module can be used to accumulate pulse counts for \u003cspan\u003eflow totalization\u003c\/span\u003e or track high-speed rotating machinery, ensuring reliable and accurate data.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Speed Processing:\u003c\/span\u003e\u003cbr\u003eCapable of handling pulse frequencies up to \u003cspan\u003e100 kHz\u003c\/span\u003e, making it ideal for applications such as \u003cspan\u003ehigh-speed flow measurement\u003c\/span\u003e and \u003cspan\u003erotating equipment monitoring\u003c\/span\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible Configuration:\u003c\/span\u003e\u003cbr\u003eEach of the 8 channels can be independently configured for \u003cspan\u003efrequency measurement\u003c\/span\u003e or \u003cspan\u003epulse totalization\u003c\/span\u003e, offering flexibility for diverse applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeries C Design:\u003c\/span\u003e\u003cbr\u003eDesigned with a \u003cspan\u003evertical\u003c\/span\u003e form factor, ensuring \u003cspan\u003ehigh-density mounting\u003c\/span\u003e and \u003cspan\u003esuperior heat dissipation\u003c\/span\u003e within \u003cspan\u003eExperion\u003c\/span\u003e cabinets, optimizing space and performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy Support:\u003c\/span\u003e\u003cbr\u003eCan be configured in a \u003cspan\u003eredundant pair\u003c\/span\u003e to ensure continuous and reliable monitoring of \u003cspan\u003ecritical flow\u003c\/span\u003e or \u003cspan\u003espeed loops\u003c\/span\u003e for high availability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGalvanic Isolation:\u003c\/span\u003e\u003cbr\u003eProvides robust electrical isolation between field wiring and the C300 controller bus to protect against surges and electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConformal Coating:\u003c\/span\u003e\u003cbr\u003eStandard \u003cspan\u003econformal coating\u003c\/span\u003e protects the module in \u003cspan\u003eClass G3 environments\u003c\/span\u003e, offering resistance to corrosion from gases and other harsh conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" width=\"NaN\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification Details\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eCC-TPIX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse Input (High Speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNumber of Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Frequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage Levels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 0 to 24 VDC (Thresholds configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01% of reading for frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (Channel-to-System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e~3.5 Watts (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCoating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eConformal Coating (Standard for \"CC\" prefix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eInstallation \u0026amp; Termination:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003eThe \u003cspan\u003eCC-TPIX11\u003c\/span\u003e module must be installed on a \u003cspan\u003eSeries C Input\/Output Termination Assembly (IOTA)\u003c\/span\u003e. The IOTA provides the physical connection points for the field wiring.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommon Pairing:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCC-TPIX11\u003c\/span\u003e: The electronic pulse input module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCC-TPIH01 \/ CC-TPIH11\u003c\/span\u003e: The corresponding \u003cspan\u003eIOTA\u003c\/span\u003e (Termination Assembly) used for non-redundant or redundant configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eApplication Note:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eFlow Totalization\u003c\/span\u003e is one of the most common uses for the \u003cspan\u003eCC-TPIX11\u003c\/span\u003e. The module performs \u003cspan\u003epulse counting locally\u003c\/span\u003e at the hardware level, ensuring accurate totalization even if the \u003cspan\u003eC300 controller\u003c\/span\u003e is processing at a slower cycle. The total pulse count is then passed to the \u003cspan\u003eExperion database\u003c\/span\u003e, supporting accurate \u003cspan\u003ebilling\u003c\/span\u003e and \u003cspan\u003eprocess control\u003c\/span\u003e.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eField Tip:\u003c\/span\u003e\u003cbr\u003eTo minimize the risk of \u003cspan\u003efalse counts\u003c\/span\u003e, ensure that the field wiring uses \u003cspan\u003eshielded twisted pair (STP) cables\u003c\/span\u003e. High-speed pulse signals are highly susceptible to \u003cspan\u003eelectromagnetic interference (EMI)\u003c\/span\u003e from nearby motors or power cables, which can disrupt accurate signal detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cspan\u003eWhy Choose the Honeywell CC-TPIX11?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHigh-Speed and Accuracy:\u003c\/span\u003e\u003cbr\u003eHandles pulse frequencies up to \u003cspan\u003e100 kHz\u003c\/span\u003e, ensuring real-time data processing for \u003cspan\u003ecritical applications\u003c\/span\u003e such as flow totalization and speed monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFlexible and Configurable:\u003c\/span\u003e\u003cbr\u003eConfigurable for \u003cspan\u003epulse accumulation\u003c\/span\u003e or \u003cspan\u003efrequency measurement\u003c\/span\u003e, providing versatility for a wide range of industrial uses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRedundancy for High Availability:\u003c\/span\u003e\u003cbr\u003eSupports \u003cspan\u003eredundant configurations\u003c\/span\u003e, ensuring \u003cspan\u003econtinuous operation\u003c\/span\u003e in critical flow or speed loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReliable in Harsh Environments:\u003c\/span\u003e\u003cbr\u003eEquipped with \u003cspan\u003econformal coating\u003c\/span\u003e, making it suitable for operation in \u003cspan\u003eClass G3\u003c\/span\u003e environments with exposure to corrosive gases or other harsh conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44096086671459,"sku":"CC-TPIX11","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/CC-TPIX11.jpg?v=1775034929","url":"https:\/\/precisemodule.com\/products\/honeywell-cc-tpix11-8-channel-high-speed-pulse-input-module-for-exhoneywell-cc-tpix11-8-channel-high-speed-pulse-input-module-for-experion%c2%ae-pks-c300perion%c2%ae-pks-c300","provider":"Precise Module Ltd.","version":"1.0","type":"link"}