{"product_id":"honeywell-dc-taox11-analog-output-24-v-system-module","title":"Honeywell DC-TAOX11 Analog Output 24 V System Module","description":"\u003ch1\u003eHoneywell DC-TAOX11 Analog Output 24 V System Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell DC-TAOX11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eDC-TAOX11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output System Module) operates as a dedicated output interface for transmitting analog control signals within Honeywell distributed control systems. The module provides analog output signal handling between control processors and connected field devices while supporting 24 V system operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"___1vyiefv f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 fe6itr f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output System Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Source\u003c\/td\u003e\n\u003ctd\u003eInput System Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eHoneywell Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003eSystem Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAnalog Output Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe DC-TAOX11 functions as an analog output interface between Honeywell controllers and field devices. The module transfers process command values generated by the control system to connected instruments and final control elements requiring analog signal communication.\u003c\/p\u003e\n\u003ch3\u003e4-20 mA and Process Control Integration\u003c\/h3\u003e\n\u003cp\u003eWithin a DCS architecture, analog output modules are used to transmit control signals to field equipment. The DC-TAOX11 supports analog signal handling as part of the process control infrastructure, enabling communication between control strategies and external devices.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the DC-TAOX11 module?\u003c\/strong\u003e\u003cbr\u003eA: It provides analog output signal transmission between the control system and connected field devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum specified output voltage?\u003c\/strong\u003e\u003cbr\u003eA: The module is specified for a maximum output voltage of 24 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module a field instrument?\u003c\/strong\u003e\u003cbr\u003eA: No. It is a control system module intended for installation within a Honeywell automation platform.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module only in compatible Honeywell system assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate analog signal wiring from high-voltage power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify terminal assignments before connecting field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain proper grounding and shield termination practices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm all wiring connections before system energization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46216357052515,"sku":"DC-TAOX11","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0549\/2775\/3315\/files\/8C-TDIL5151306969-175_1.jpg?v=1788422031","url":"https:\/\/precisemodule.com\/products\/honeywell-dc-taox11-analog-output-24-v-system-module","provider":"Precise Module Ltd.","version":"1.0","type":"link"}